CNC Electric · YCB9-80H
Product overview
The CNC Electric YCB9-80H is a high-capacity thermal-magnetic miniature circuit breaker. This page covers the original four-pole C63 sample documented in the manufacturer CB report: 63A, 400/415V AC, 50/60Hz and 10kA under IEC/EN 60898-1. The original H marking and product photographs are retained.
Technical selection summary
| Manufacturer model | YCB9-80H |
|---|---|
| Published configuration | 4P, C63: 63A, C curve |
| Voltage / frequency on the original sample | 400V / 415V AC, 50/60Hz |
| Rated short-circuit capacity Icn | 10,000A under IEC/EN 60898-1; H version |
| Protection functions | Thermal overload, magnetic short-circuit protection and isolation |
| Poles | 4 poles; use the original four-pole wiring diagram, not a 3P+N assumption |
| Standard marked on the unit | IEC/EN 60898-1 |
| C-curve instantaneous tripping | 5–10 × In; follow the original test table |
| Insulation voltage Ui | 500V, shared manufacturer catalogue |
| Impulse withstand voltage Uimp | 4kV, shared manufacturer catalogue |
| Mechanical / electrical life | 20,000 / 10,000 operations, current shared catalogue |
| Protection / pollution degree | IP20 / 2 |
| Reference temperature | 30°C |
| Operating ambient | −5°C to +40°C; 24-hour average ≤35°C, shared catalogue |
| Terminal capacity / tightening torque | 25mm² / 2N·m, shared catalogue |
| Mounting | 35mm EN60715 DIN rail |
| Dimensions | Use the 4P row of the original YCB9-80M/H drawing |
| Original photo evidence | Manufacturer CB report 230501073SHA-001, marking plate page 4 and 4P H sample photos pages 127–129 |
Selection and installation
This listing is the original 4P C63 H sample, with 400/415V AC and 10,000A markings. It is kept separate from the 6kA M version and from unrelated factory M-labelled photographs. The CB report expressly identifies these photos as YCB9-80H; the shared catalogue is supplied for model and pole-specific technical reference. Do not use this AC breaker for DC PV strings or assume residual-current protection. Confirm prospective short-circuit current, conductor sizing and upstream coordination before selection.
Typical applications
Four-pole AC distribution circuits in commercial and industrial panels requiring coordinated overload and short-circuit protection.
Original technical data and drawings
The following manufacturer figures retain the original technical content. Dimensions are in millimetres unless otherwise marked. Refer to the model and frame labels when using a shared family drawing.