NewTrend · filtered AC power entry
Product overview
The K2A-6A-T combines an IEC AC power inlet, fuse holder and EMI filter in a compact metal module. Rated for up to 6A and 250V AC, it provides filtered AC input for compatible electronic equipment. The inlet is panel-mounted, with separate load terminals on the rear.
Technical selection summary
| Model | K2A-6A-T |
|---|---|
| Product type | IEC AC power inlet with EMI filter and integrated fuse holder |
| Rated current | 6A |
| Maximum continuous operating voltage | 250V AC |
| Frequency | 50/60Hz |
| Nameplate reference | 115/250V AC |
| High-potential test, 1 minute | Line-to-line 1500V DC; line-to-ground 1500V AC |
| Leakage current at 250V AC, 50/60Hz | <0.5mA |
| Y capacitor reference | 3.3nF |
| Resistance reference | 1500kΩ |
| Operating / storage temperature | −25°C to +85°C |
Filter and electrical connections
The filter network includes line and neutral paths, inductive elements and capacitors to suppress conducted interference. Connect the protective earth terminal to the equipment chassis and follow the line/load markings on the module. Select a fuse appropriate to the equipment and verify its rating and installation before use.
Construction and mounting
The module combines a metal filter enclosure with a front IEC inlet and accessible fuse holder. Mount the flange securely to the panel and provide clearance for the rear connections and insulated wiring. Isolate the supply before changing a fuse or servicing the equipment.
Dimensions
The dimension drawing shows the inlet flange, mounting holes, body and rear terminal projection. Use the drawing to check the panel opening and clearance for the installed wiring.
Typical applications
AC power entry for compatible measurement equipment, electronic instruments, industrial electronics and office or test equipment within the module ratings.