NewTrend · enclosed AC/DC switching power supplies
Product overview
The RSP power supplies provide a single DC output from a 100–240V AC input. Choose RSP-320-24 for 24V DC at 13.4A or RSP-1000-12 for 12V DC at 83A. Both use a ventilated metal enclosure and screw terminals, with active power-factor correction and adjustable output voltage.
Technical selection summary
| RSP-320-24 | 320W series; 24V DC / 13.4A nameplate output |
|---|---|
| RSP-1000-12 | 1000W series; 12V DC / 83A nameplate output |
| Input voltage | 100–240V AC, 50/60Hz |
| Input nameplate current | RSP-320-24:4A; RSP-1000-12:12–5A |
| Power factor correction | Active PFC |
| Voltage adjustment | Front adjustment control; approximately ±10% |
| RSP-1000 controls | Separate ADJ-V voltage and ADJ-A current adjustment |
| RSP-320 controls | Front voltage adjustment and temperature-controlled cooling fan |
| Protection functions | Short circuit, overload, overvoltage and overcurrent |
| Enclosure | Ventilated metal case with screw-terminal connections |
| RSP-320 dimensions | 215mm long × 115mm wide × 30mm high |
| RSP-1000 dimensions | 280mm long × 126mm wide × 40mm high |
| Working temperature | −20°C to +70°C |
| Storage temperature | −40°C to +85°C |
| Ambient humidity | 0–95% RH, non-condensing |
| Installation | Dry, ventilated electrical enclosure; protective earth connection required |
RSP-320-24 connections and fan cooling
The 24V version provides three positive and three negative output terminals, followed by protective earth, neutral and line input terminals. The front ADJ control adjusts the output voltage. Its fan operates automatically according to working temperature; keep sufficient free space around the fan and ventilation openings.
RSP-1000-12 output and adjustment
The 12V version uses separate high-current negative and positive DC terminals. Its AC input terminals are marked N, L and protective earth. Separate ADJ-V and ADJ-A controls provide voltage and current adjustment, as identified in the diagram below. Use conductors and circuit protection appropriate to the connected load and terminal ratings.
Protection and installation
Short-circuit, overload, overvoltage and overcurrent protection are provided. Install inside a dry electrical enclosure, bond the metal case to protective earth and keep all cooling paths unobstructed. Isolate the AC input before wiring or servicing. The high-voltage warning on the cover applies even though the output is low-voltage DC; do not remove the cover while energized.
RSP-320 dimensions
The RSP-320 enclosure measures 215mm long,115mm wide and 30mm high. Allow additional clearance for the terminal cover, conductors and fan ventilation.
RSP-1000 dimensions
The RSP-1000 enclosure measures 280mm long,126mm wide and 40mm high. The output-terminal arrangement and mounting outline differ from the RSP-320 version.
Typical applications
For DC loads in automation equipment, instrumentation, communications installations and lighting systems requiring the selected 12V or 24V output. Select the complete model to match voltage, current and available installation space.