NewTrend · Staircase lighting timer switch
Product overview
NewTrend RT8-LS controls delayed lighting in stairways, corridors, entrances and halls. Its adjustable 0.5-20 minute interval and 16A AC-1 normally open output suit compact lighting-control panels. The front switch selects permanent ON, timed AUTO operation or permanent OFF. The 18mm housing mounts on a DIN rail and uses an AC 230V supply.
Technical selection summary
| Model | RT8-LS |
|---|---|
| Output contacts | 1 SPST (NO) |
| Function | ON / AUTO timing / OFF |
| Control supply | AC 230V, 50-60Hz |
| Supply terminals | L-N |
| Power input | AC maximum 6VA / 1.3W |
| Time setting | Potentiometer, 0.5-20 minutes |
| Minimum power-on time | 200ms |
| Illuminated pushbuttons | N-3 or L-3; maximum 50mA |
| Glow-lamp reference | Maximum 75 lamps at 230V, tested with 0.68mA/230VAC glow lamps |
| Weight | 61g |
| Supply tolerance | -15% to +10% |
| Supply indication | Green LED |
| Time setting deviation | 10% with mechanical adjustment |
| Repeat accuracy | 0.2% of set value |
| Temperature coefficient | 0.05%/degree C at 20 degrees C |
| Contact rating | 16A, AC-1 |
| Switching voltage | 250VAC / 24VDC |
| Minimum DC breaking power | 500mW |
| Output indication | Red LED |
| Mechanical life | 10,000,000 operations |
| Electrical life (AC-1) | 100,000 operations |
| Reset time | Maximum 200ms |
| Operating temperature | -20 to +55 degrees C |
| Storage temperature | -35 to +75 degrees C |
| Mounting | DIN rail to EN/IEC 60715 |
| Protection | IP40 front panel; IP20 terminals |
| Operating position | Any |
| Overvoltage category | III |
| Pollution degree | 2 |
| Maximum conductor size | Solid: 1 x 2.5mm2 or 2 x 1.5mm2; with sleeve: 1 x 2.5mm2 (AWG 12) |
| Terminal tightening torque | 0.8Nm |
| Body dimensions | 90 x 18 x 64mm |
| Referenced standards | EN 61812-1; IEC 60669-2-3; IEC 60947-5-1 |
| Incandescent lamps | 2000W |
| Halogen lamps | 2000W |
| Fluorescent lamps | 1000W |
| Parallel-corrected fluorescent lamps | 900W, 125uF |
| Compact fluorescent lamps | 400W |
| LED lamps | 300W |
Select the operating sequence and wiring arrangement for the installation. The 16A AC-1 rating is not a universal lamp-load rating; use the lamp-specific limits and verify inrush current.
Operation
- The AUTO timing chart shows control-input response; ON and OFF force the corresponding output state.
- Use the connection diagram that matches the installation wiring. Illuminated pushbuttons are supported within the stated current and quantity limits.
Typical applications
- Stairway, corridor and entrance lighting
- Hall and common-area lighting control
- Delayed fan control where the load and operating sequence are suitable
Specify your enquiry
For a focused quotation, include:
- AC 230V supply, installation wiring arrangement and desired operating sequence
- Lamp technology, individual lamp wattage, total load and inrush current
- Required delay interval, illuminated pushbuttons and quantity
Download NewTrend RT8-LS datasheet (PDF)
Product reference images and drawings
Three-wire and four-wire connection diagrams
AUTO timing and ON/OFF operation
Lamp-load reference limits
RT8-LS housing dimensions.
Set the front selector to ON for permanent output, AUTO for timed operation, or OFF for permanent release. In AUTO, set the required 0.5-20 minute interval using the potentiometer. Installation and wiring must be performed by qualified electricians.