People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
  • Home
  • Products
    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Automation & Control

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Circuit Breaker & Fuses

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Din-Rail Mounted Products

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Distribution Box & Cabinet

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Load Center & Meter Bases

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Solar PV Products

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Electrical Accessories

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
Search
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
Click to enlarge
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
Home Electrical Accessories Others People Electrical Materials People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V
NewTrend 2073390 Replacement Screed Service Kit for AB600-2 TV
NewTrend 2073390 Replacement Screed Service Kit for AB600-2 TV
Back to products
LC1K06 3-Pole 6A AC Contactor 110V Coil NO/NC Options
LC1K06 3-Pole 6A AC Contactor 110V Coil NO/NC Options

People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V

Original People Electric XJ01 enclosed reduced-voltage autotransformer starter for three-phase AC380V, 50Hz squirrel-cage motors. Select a documented 14–300kW model and confirm motor current, starting duty and tap requirements.

Model
Motor Power
Request a Quote

Send quantities and requirements together. Availability and final specifications are confirmed with your quotation.

SKU: XJ01 Categories: People Electrical Materials, People Motor Drive Protection
  • Description
  • Additional information
  • Technical Documents
  • Selection & Ordering
Description

People Electric · Autotransformer Motor Starter

Product overview

People Electric XJ01 starting boxes use an autotransformer to reduce the voltage applied during infrequent motor starts. The enclosed assembly incorporates contactors, a thermal relay and a time relay. Match the documented starter size to the motor nameplate, load characteristics and permitted starting duty.

Technical selection summary

Manufacturer / seriesOriginal People Electric XJ01
Supply / motorThree-phase AC380V, 50Hz; squirrel-cage induction motor
Documented models / maximum motor powerXJ01-14: 14kW; XJ01-17: 17kW; XJ01-22: 22kW; XJ01-30: 30kW; XJ01-40: 40kW; XJ01-55: 55kW; XJ01-75: 75kW; XJ01-90: 90kW; XJ01-100: 100kW; XJ01-115: 115kW; XJ01-135: 135kW; XJ01-155: 155kW; XJ01-190: 190kW; XJ01-225: 225kW; XJ01-260: 260kW; XJ01-300: 300kW
Maximum operating current by modelXJ01-14: 28A; XJ01-17: 34A; XJ01-22: 43A; XJ01-30: 58A; XJ01-40: 77A; XJ01-55: 110A; XJ01-75: 142A; XJ01-90: 170A; XJ01-100: 190A; XJ01-115: 218A; XJ01-135: 256A; XJ01-155: 300A; XJ01-190: 350A; XJ01-225: 410A; XJ01-260: 480A; XJ01-300: 530A
Starting taps65% and 80% of rated voltage; source default is 65%. Confirm the required connection and motor starting torque.
Starting timeTime relay adjustment 1–15s; set for the actual load
OperationAutomatic operation is described for smaller models; manual and automatic operation for 90kW and above. Confirm the exact controls supplied, particularly the 75kW boundary.
Protection / assemblyAutotransformer, contactors, thermal relay and time relay in an enclosure; confirm overload setting and upstream short-circuit protection
Overall size, W × H × D14–30kW: 400 × 700 × 280mm; 40–75kW: 500 × 1000 × 310mm; 90–115kW: 550 × 1260 × 420mm; 135–190kW: 610 × 1440 × 490mm; 225–300kW: 700 × 1700 × 590mm
Mounting centres E × F14–30kW: 370 × 120mm; 40–75kW: 470 × 230mm; 90–115kW: 490 × 280mm; 135–190kW: 560 × 325mm; 225–300kW: 645 × 410mm. Source tolerance ±5mm; holes 10mm except 225–300kW 12mm.
EnvironmentIndoor; altitude <2,000m; -5 to +40°C, daily average ≤35°C; RH ≤50% at +40°C; pollution class III; mounting inclination ≤5°
Standards stated by manufacturerGB 14048.4; IEC 60947

Selection is limited to the 14–300kW models explicitly tabulated in the manufacturer catalogue. The introductory 400kW upper range is not added as an undocumented option. Confirm actual motor current, start duration/frequency, tap selection, thermal-relay/CT coordination and the complete supplied configuration before order.

Typical applications

  • Reduced-voltage starting of three-phase industrial squirrel-cage motors.
  • Infrequent motor starts where an enclosed autotransformer starter matches the load and supply.

Specify your enquiry

For a focused quotation, include:

  • Selected XJ01 power, motor nameplate current, AC380V/50Hz supply and load type.
  • Starting time, starts per hour, required 65%/80% tap and manual/automatic controls.
  • Overload setting, upstream protective device, enclosure requirements, quantity and destination.

Download People Electric XJ01 catalogue (PDF)

Product reference images and drawings

People Electric XJ01 technical-1

People Electric XJ01 technical-2

People Electric XJ01 technical-3

People Electric XJ01 technical-4

Additional information
Model

XJ01

Motor Power

14kW, 17kW, 22kW, 30kW, 40kW, 55kW, 75kW, 90kW, 100kW, 115kW, 135kW, 155kW, 190kW, 225kW, 260kW, 300kW

Technical Documents

TECHNICAL RESOURCES

Documents for People Electric XJ01 Autotransformer Motor Starter, 14–300kW, AC380V

Check the exact model, rating and configuration in the linked document before ordering.

Download People Electric XJ01 manufacturer catalogue (PDF) ↗

Drawings and compliance documents

Tell us the model and destination market if you need dimensions, a wiring diagram or a certification document. Available documents and approvals depend on the exact product configuration.

Ask for product documents

Supplier: Shanghai Newtrend Electric Co., Ltd. Brand and manufacturer details are stated separately for each product.

Selection & Ordering

BEFORE YOU ORDER

Selection and ordering questions

What information is needed for a quotation?

Send the exact model or selected configuration, required quantity, destination country and any project-specific requirements. Our team will confirm availability and the matching specification.

Are the same approvals available for every configuration?

No. Standards, certificates and market acceptance must be checked for the exact manufacturer model and configuration. Request the relevant document before specifying the product.

Can I include other products in the same enquiry?

Yes. Add the required products to your quote list, set the quantities and send one enquiry with your project requirements.

Related products

People Electric RDX30-32 1P+N Miniature Circuit Breaker, 1–32A 4.5kA
People Electric RDX30-32 1P+N Miniature Circuit Breaker, 1–32A 4.5kA

People Electric RDX30-32 1P+N Miniature Circuit Breaker, 1–32A 4.5kA

Original People Electric RDX30-32 AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric RDC8 AC Contactor, 150–700A AC-1
People Electric RDC8 AC Contactor, 150–700A AC-1

People Electric RDC8 AC Contactor, 150–700A AC-1

Original People Electric RDC8 three-pole AC contactor, 150–700A AC-1. Specify the exact AC control supply in your enquiry; 110–660V denotes the catalogue range, not a universal coil rating.
People Electric CJX2-115–630 3-Pole AC Contactor, 115–630A AC-3
People Electric CJX2-115–630 3-Pole AC Contactor, 115–630A AC-3

People Electric CJX2-115–630 3-Pole AC Contactor, 115–630A AC-3

Original People Electric CJX2-115-630 AC contactor. Select the documented current and control configuration for the actual load.
People Electric JR20 Thermal Overload Relay, 0.1–630A
People Electric JR20 Thermal Overload Relay, 0.1–630A

People Electric JR20 Thermal Overload Relay, 0.1–630A

Original People Electric JR20 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A

People Electric JRS8 Thermal Overload Relay, 0.1–500A

Original People Electric JRS8 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.
People Electric RDB67-63 Miniature Circuit Breaker, 2–63A 6kA
People Electric RDB67-63 Miniature Circuit Breaker, 2–63A 6kA

People Electric RDB67-63 Miniature Circuit Breaker, 2–63A 6kA

Original People Electric RDB67-63 AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric DZ47-63 Miniature Circuit Breaker, 2–63A 4.5kA
People Electric DZ47-63 Miniature Circuit Breaker, 2–63A 4.5kA

People Electric DZ47-63 Miniature Circuit Breaker, 2–63A 4.5kA

Original People Electric DZ47-63 AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric RDT8-PV Photovoltaic DC Fuse & Holder, 1000/1500V
People Electric RDT8-PV Photovoltaic DC Fuse & Holder, 1000/1500V

People Electric RDT8-PV Photovoltaic DC Fuse & Holder, 1000/1500V

Original People Electric RDT8-PV photovoltaic fuse links and matching holders. Choose the component first: 10×38 at DC1000V or 10×85 at DC1500V. Holders and fuse links are ordered separately.
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
      • People Electrical Materials
        • People Industrial Plugs & Sockets
        • People Rectifiers & Thyristors
        • People Terminal Blocks
        • People MCB
        • People RCCB RCBO
        • People MCCB ACB
          • People Air Circuit Breakers
          • People Moulded Case Circuit Breakers
        • People Contactor & Overload Relays
        • People Relays
        • People Fuse & Disconnectors
        • People Inverter & Soft Starters
        • People Pushbutton & Pilot Lights
        • People Changeover Switches
        • People Capacitor & Reactors
        • People Voltage Stabilizers
        • People New Energy
        • People Motor Drive Protection
        • People Master Switches
        • People Control Transformers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • NewTrend LE1D Enclosed DOL Starter with Overload Relay, 9-95A NewTrend LE1D Enclosed DOL Starter with Overload Relay, 9-95A
  • DC88P 500A 12V/24V Superwinch WARN Replacement ATV Winch Solenoid DC88P 500A 12V/24V Superwinch WARN Replacement ATV Winch Solenoid
  • DELIXI ACL Input / OCL Output Three-Phase Reactor DELIXI ACL Input / OCL Output Three-Phase Reactor
  • Long Life 2-Pole Solar DC Circuit Breaker for PV Panels Long Life 2-Pole Solar DC Circuit Breaker for PV Panels
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...

    Request a Quote 0 WhatsApp

    SHANGHAI NEWTREND ELECTRIC

    Your quote request

    Select products, add quantities and tell us what you need.

    You can send a general enquiry, or browse our products and add items to this list.

    We use your details to respond to this enquiry. Privacy policy

    Continue browsing