DELIXI DC control contactor for motor control and switching applications.
DELIXI CJX2H-Z DC Control Contactor
DELIXI DC control contactor for motor control and switching applications.
📄 Technical Documentation & Product Specifications
Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for DELIXI CJX2H-Z DC Control Contactor.
💡 Frequently Asked Technical Questions & Selection Guide
Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.
How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?
AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.
How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?
Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.
How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?
Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.
What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?
Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.
How do ambient temperature and installation altitude affect contactor performance?
Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.