ELR-3C Earth Leakage Relay ELR-3C Earth Leakage Relay
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
ELR-3C Earth Leakage Relay ELR-3C Earth Leakage Relay
Search
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
Click to enlarge
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
Home Automation & Control Relays ELR-3C Earth Leakage Relay
QO 1-Pole Plug-In Circuit Breaker General Type
QO 1-Pole Plug-In Circuit Breaker General Type
Back to products
QX4A Automatic Star Delta Reduced Voltage Motor Starter
QX4A Automatic Star Delta Reduced Voltage Motor Starter

ELR-3C Earth Leakage Relay

Size:Miniature
Brand Name:NewTrend
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:ELR-3C
Contact Load:0.025A – 25A
Protect Feature:Sealed
SKU: 1769739477976096768 Category: Relays
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

ELR-3C RDC-02 Earth Leakage Relay with toroidal current transformer

   

ELR-3C Earth Leakage Relay, maintain all the basic characteristics of the DIN 96×96 mm series, although its reduced dimensions. It is one of the relays series, built in a modular enclosure, according with DIN 43880 Standard, with a three modules module base 17.5 mm. Its wide setting ranges allows to select the tripping current, in order that the contact voltage values are maintained below 50V as required by the CEI 64-8 Standard. This is also the suitable answer for a proper selectivity, whenever there are other ELR’s or/and RCD’s downstream or upstream in the line to be protected.

 

An outstanding characteristic of the present relays, is the permanent control of the Toroidal – ELR circuit. Its interruption brings along the immediate trip of the protection. This allows to identify the anomaly, without waiting to the periodical control, made with the Test push button. The instrument , fitted with filters at the input circuits, is practically immune to external disturbances, so as the pulse currents with dc components, complying with the requirements of VDE 0664 and project IEC 23 Standards. The ELR-3C has the possibility of an automatic or manual reset, selectable by a micro switch and to protect the settings by its sealable transparent front cover. This relay accepts also the possibility of a remote test. It may also be coupled to any of our CT-1 Toroidal Transformers.

 

311.jpg312.jpg111.JPG116.jpg

 

 

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for ELR-3C Earth Leakage Relay.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

SUL181d SYN161d 24-Hour Analogue Daily Program Time Switch

SUL181d SYN161d 24-Hour Analogue Daily Program Time Switch

Brand Name:Newtrend
Place of Origin:China
Max. Current:16A
Model Number:SUL181d SYN161d
Max. Voltage:240V
Channel:1 channel
Program:Daily Program
Operating Voltage:230-240VAC/110VAC/24VDC/12VDC
Type:96 switching segments
Mini. Interval:Shortest switching time 15 minutes
ON/OFF operation:Permanent ON/AUTO/continuous OFF
SUL181h Weekly Programmable Time Switch
SUL181h Weekly Programmable Time Switch

SUL181h Weekly Programmable Time Switch

Frequency:50Hz,60Hz
Theory:Electronic
Whether the smart:NO
Brand Name:Newtrend
Application:Industrial Equipment,Home Appliances,security systems,Gardening and Irrigation Systems,Automated Control
Material:abs,copper
Place of Origin:China
Max. Current:16A
Model Number:SUL181h SYN161h
Max. Voltage:240V
IP level:IP41
Channel:1 channel
Program:Daily Program
Operating Voltage:230-240VAC/110VAC/24VDC/12VDC
Type:48 switching segments
Shortest switching time:30 minutes
ON/OFF operation:Permanent ON / Permanent OFF
Certification:CCC, CE
SUL160a Weekly Programmable Time Switch

SUL160a Weekly Programmable Time Switch

Frequency:50Hz,60Hz
Theory:Electronic
Whether the smart:NO
Brand Name:Newtrend
Application:Industrial Equipment,Home Appliances,security systems,Gardening and Irrigation Systems,Automated Control
Material:abs,copper
Place of Origin:China
Max. Current:16A
Model Number:SYN160a SUL160a SUL180a
Max. Voltage:240V
Channel:1 channel
Program:Daily Program
Operating Voltage:230-240VAC/110VAC/24VDC/12VDC
Type:96 switching segments
Shortest switching time:15 minutes
ON/OFF operation:Permanent ON/AUTO/continuous OFF
MK2P MK3P DPDT 3PDT Plug-in Relay (10A)

MK2P MK3P DPDT 3PDT Plug-in Relay (10A)

Size:Miniature
Brand Name:Newtrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:MK2P MK3P
Contact Load:High Power
Protect Feature:Sealed
SYN161d Digital Weekly Time Switch

SYN161d Digital Weekly Time Switch

Frequency:50Hz,60Hz
Theory:Electronic
Whether the smart:NO
Brand Name:Newtrend
Application:Industrial Equipment,Home Appliances
Material:abs,copper
Place of Origin:China
Max. Current:16A
Model Number:SYN161d
Max. Voltage:240V
Channel:1 channel
Program:Daily Program
Operating Voltage:230-240VAC/110VAC/24VDC/12VDC
Power Reserve:without
Type:96 switching segments
Mini. Interval:Shortest switching time 15 minutes
ON/OFF operation:Permanent ON/AUTO/continuous OFF
THC Weekly Programmable DIN Rail LCD Digital Timer Switch
THC Weekly Programmable DIN Rail LCD Digital Timer Switch

THC Weekly Programmable DIN Rail LCD Digital Timer Switch

Type:Mini
Brand Name:GEYA
Theory:Digital
Place of Origin:China
application:Timer Switch
Model Number:THC-15A THC-20A THC-30A
55.32 55.34 Plug-in General Purpose Relay (DPDT/4PDT)

55.32 55.34 Plug-in General Purpose Relay (DPDT/4PDT)

Size:Miniature
Brand Name:Newtrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:55 series
Contact Load:High Power
Protect Feature:Sealed
Contact Configuration:2CO 3CO 4CO
Rated Current:10A 5A
70.2 70.3 General Purpose Power Relay
70.2 70.3 General Purpose Power Relay

70.2 70.3 General Purpose Power Relay

Size:Miniature
Brand Name:Newtrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:70.2 70.3
Contact Load:High Power
Protect Feature:Sealed
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • SUL181d SYN161d 24-Hour Analogue Daily Program Time Switch SUL181d SYN161d 24-Hour Analogue Daily Program Time Switch
  • SUL181h Weekly Programmable Time Switch SUL181h Weekly Programmable Time Switch
  • 60.12 60.13 Plug-in Electromagnetic Power Relay with LED 60.12 60.13 Plug-in Electromagnetic Power Relay with LED
  • SYN161d Digital Weekly Time Switch SYN161d Digital Weekly Time Switch
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the plane.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...