CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker
Search
Sold out
CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker
Click to enlarge
Home Electrical Accessories Others CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker
CHINT NC1-1810/1801 3P 18A Magnetic Contactor Multiple Voltages
CHINT NC1-1810/1801 3P 18A Magnetic Contactor Multiple Voltages
Back to products
DC182 Magnetic Contactor Repair Kit for Linde Forklift
DC182 Magnetic Contactor Repair Kit for Linde Forklift

CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker

Brand Name:Chint
Place of Origin:China
Model Number:NA1
Rated Frequency (Hz):50/60Hz
Protection:LSI
Breaking Capacity:25kA – 100kA
Rated Voltage:400V, 690V
Type:Air
Poles
Rated Current
SKU: 1600722064627 Category: Others
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Chint NA1 series air circuit breaker is suitable for AC 50Hz/60Hz circuits with rated operational voltage 400V and 690V,
and rated current up to 6300A. It is mainly used to distribute electric energy and to protect circuits and electrical equipment
against overload, under-voltage, short-circuit, and single-phase earthing fault. Typical applications include power stations,
factories, mines, and modern high-rise building distribution systems.

  • High current application: suitable for low-voltage distribution systems with rated current up to 6300A.
  • Voltage options: suitable for 400V and 690V AC systems.
  • Protection capability: used for overload, under-voltage, short-circuit, and single-phase earthing fault protection.
  • Protection type: LSI.
  • Breaking capacity range: 25kA – 100kA.
  • Standard reference: IEC/EN 60947-2.

Technical Specifications

Parameter Specification
Model Series NA1
Type Air Circuit Breaker (ACB)
Rated Frequency 50Hz / 60Hz
Rated Voltage 400V / 690V AC
Rated Current Up to 6300A
Protection LSI
Breaking Capacity 25kA – 100kA
Standard IEC/EN 60947-2
Type designation
 

   

Structure
 

 

 

 

Technique Parameters
 

 

 

 

Accessories
 

 

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Rated Current

200A – 6300A

Poles

3P, 4P

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for CHINT NA1 ACB 3P/4P 1000A-4000A AC/DC Air Circuit Breaker.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Trip Unit Protection

How to choose between Thermal-Magnetic (TMD) and Electronic (Micrologic) trip units?

A

Thermal-magnetic trip units provide fixed or adjustable bimetallic overload and electromagnetic instantaneous short-circuit protection, ideal for standard industrial power distribution. Electronic microprocessor trip units offer precise digital dials for L (Long-time delay overload), S (Short-time delay short-circuit), I (Instantaneous short-circuit), and G (Ground-fault protection), delivering total time-current selectivity in modern switchgear.

Ics vs Icu Capacity

What is the technical distinction between Ultimate (Icu) and Service (Ics) breaking capacity?

A

Icu represents the absolute maximum fault current the breaker can safely interrupt, after which inspection or replacement may be needed. Ics represents the operational breaking capacity (50%, 75%, or 100% of Icu) that the breaker can clear repeatedly and remain fully operational without performance degradation. In critical healthcare, data center, and continuous industrial applications, specify breakers with Ics = 100% Icu.

3P vs 4P Neutral

When should a 4-Pole (4P) MCCB be specified instead of a standard 3-Pole (3P) MCCB?

A

A 4P breaker with a switched neutral is required in systems with dual power sources (generator / utility ATS transfer) to prevent circulating neutral currents, in IT distribution networks, and in commercial installations with heavy non-linear harmonic loads (LED drivers, variable speed drives) where neutral conductor current can exceed phase currents.

Motorized & Remote Operation

How to select manual rotary handles vs motorized electric operating mechanisms?

A

Direct or extended door rotary handles are specified when the MCCB is enclosed inside switchgear cubicles, providing padlocking and door-interlock safety. Motor operating mechanisms (electric operators) are required for automated SCADA control, remote PLC open/close operations, and automatic transfer switch (ATS) integration.

Terminal & Mounting Options

What terminal connection hardware and mounting configurations are available?

A

Standard front connection lugs accept copper or aluminum compression terminals and busbar connections. For high-density panel boards, extended spreader terminals, rear connection studs, and plug-in / draw-out base cassettes are available to facilitate rapid maintenance and modular swap-out.

Related products

LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options

LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC2K06
Phase:3
Main Circuit Rating Current:6A
type:Reversing contactor
Certificate:CE, ROHS
THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker
THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker

THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:220V,230V,240V,120V
Sold out
LC1D258 LC1DT40 4P 40A AC Contactor 24V-380V Coil Options

LC1D258 LC1DT40 4P 40A AC Contactor 24V-380V Coil Options

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D258
Phase:3
Main Circuit Rating Current:25A
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K LP1K
Phase:3
Main Circuit Rating Current:6A 9A 12A 16A
type:Magnetic contactor
Sold out
THQL1115 1-Pole 15A 120V/240V Q-Line Plug-in Circuit Breaker
THQL1115 1-Pole 15A 120V/240V Q-Line Plug-in Circuit Breaker

THQL1115 1-Pole 15A 120V/240V Q-Line Plug-in Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:220V,230V,240V,380V
Albright Equivalent DC88-P Series 24VDC 100A Reversing Contactor

Albright Equivalent DC88-P Series 24VDC 100A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC88P
Phase:1
Main Circuit Rating Current:500A
LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A
LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A

LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • NewTrend SP-02 IP66 ABS plastic CE ROHS EAC UKCA Waterproof Electrical Junction Boxes NewTrend SP-02 IP66 ABS plastic CE ROHS EAC UKCA Waterproof Electrical Junction Boxes
  • Tmax T7S 1200A UL489 MCCB 3P/4P PR232/P LSI Tmax T7S 1200A UL489 MCCB 3P/4P PR232/P LSI
  • CHINT NQ3 Series Low Voltage Electromagnetic DOL Starter CHINT NQ3 Series Low Voltage Electromagnetic DOL Starter
  • DELIXI VFD For Crane DELIXI VFD For Crane
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the plane.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...