Chint NCH8 Modular Contactor Chint NCH8 Modular Contactor
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint NCH8 Modular Contactor Chint NCH8 Modular Contactor
Search
Sold out
Chint NCH8 Modular Contactor
Chint NCH8 Modular Contactor
Chint NCH8 Modular Contactor
Chint NCH8 Modular Contactor
Click to enlarge
Chint NCH8 Modular Contactor
Chint NCH8 Modular Contactor
Chint NCH8 Modular Contactor
Chint NCH8 Modular Contactor
Home Chint Electrical Materials Chint Contactor & Overload Relays Chint NCH8 Modular Contactor
Chint CJ19 Contactor for Capacitor Switching
Chint CJ19 Contactor for Capacitor Switching
Back to products
Chint NC2 Contactor
Chint NC2 Contactor

Chint NCH8 Modular Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NCH8
Phase:3
Main Circuit Rating Current:20A 25A 40A 63A
Poles
Rated Current (AC-3)
Coil Voltage
SKU: 1600649871074 Category: Chint Contactor & Overload Relays

Where to Use NCH8 Contactor?

The Chint NCH8 Modular Contactor is an industrial-grade AC contactor designed for building automation, lighting control, heating systems, and small motor control in distribution boards. With current ratings from 0.1A - 630A and 3P / 4P pole configuration.

Technical Specifications

Model SeriesNCH8
Rated Current (AC3)0.1A - 630A
Pole Configuration3P / 4P
Coil Voltage220V/380V AC/DC
Utilization CategoryAC-3 (Motor Control) / AC-1 (Resistive)
StandardIEC 60947-4-1

Frequently Asked Questions

Q: How do I select the right contactor size for my motor?

A: The contactor should be rated for at least the motor's full load current (FLC). For AC-3 duty, use the motor's rated current. For heavy start applications, consider the next size up.

Q: Do I need an overload relay with this contactor?

A: Yes, a contactor provides switching control but does NOT protect against motor overload. You need a thermal overload relay (such as Chint NR2/NXR series) mounted directly below the contactor.

  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Chint NCH8 20A 25A 40A 63A NCH8-20/20 NCH8-20/11 NCH8-40/20 NCH8-40/40 NCH8-63/40 NCH8-63/22 CHNT Din rail Modular Contactor

   

Chint NCH8 Modular AC Contactor 20~63A

1. General
1.1 Electric ratings: up to 20A, 25A, 40A, 63A, 230V, 400V AC50/60Hz;
1.2 Utilization category: AC-1, AC-7a, AC-7b;
1.3 Standard: IEC/EN 61095

 

2. Features
2.1 Compact design and modularization design;
2.2 Insulation material with excellent performances has been adopted to enhance the operation security to a great extent;
2.3 Elegant appearance. A mounting instruction diagram is appended for convenient operation;
2.4 No noise during operation.
2.5 IP20

 

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Poles

1P 1NO, 1P 1NC, 2P 2NO, 2P 1NO+1NC, 2P 2NC, 4P 4NO, 4P 3NO+1NC, 4P 2NO+2NC

Rated Current (AC-3)

20A, 25A, 40A, 63A

Coil Voltage

AC 24V, AC 220V, AC 230V, AC 240V

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for Chint NCH8 Modular Contactor.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

Chint NC2 Contactor
Chint NC2 Contactor

Chint NC2 Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NC2
Phase:3
Main Circuit Rating Current:630A,400A,115A,150A,185A,225A,265A,330A,500A,800A
Chint NXR Thermal Overload Relay
Chint NXR Thermal Overload Relay

Chint NXR Thermal Overload Relay

Brand Name:Chint
Theory:Thermal Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NXR
Contact Load:High Power
Protect Feature:Sealed
Sold out
Chint NC1 4P 2NO+2NC Contactor
Chint NC1 4P 2NO+2NC Contactor

Chint NC1 4P 2NO+2NC Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NC1
Phase:3
Main Circuit Rating Current:9A - 95A
Sold out
Chint CJ20 Contactor
Chint CJ20 Contactor

Chint CJ20 Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:CJ20
Phase:3
Main Circuit Rating Current:10A ~ 630A
Chint NC1 4P 4NO Contactor

Chint NC1 4P 4NO Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NC1
Phase:3
Main Circuit Rating Current:9A - 95A
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay

Chint NRE8 Electronic Overload Relay

Brand Name:Chint
Theory:Thermal Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NRE8
Contact Load:High Power
Protect Feature:Sealed
Sold out
CHINT NC1 AC Contactor for Motor Control and Industrial Panels
CHINT NC1 AC Contactor for Motor Control and Industrial Panels

CHINT NC1 AC Contactor for Motor Control and Industrial Panels

CHINT NC1 AC contactor is a reliable choice for motor control, industrial panels, and OEM electrical assemblies. It offers practical current options for distributors, panel builders, and export buyers.

Sold out
Chint NCK3 Definite Purpose Contactor
Chint NCK3 Definite Purpose Contactor

Chint NCK3 Definite Purpose Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NCK3
Phase:3
Main Circuit Rating Current:20A-40A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NCK5 Definite Purpose Contactor Chint NCK5 Definite Purpose Contactor
  • Chint CJ19 Contactor for Capacitor Switching Chint CJ19 Contactor for Capacitor Switching
  • Chint NCK3 Definite Purpose Contactor Chint NCK3 Definite Purpose Contactor
  • Chint CJ20 Contactor Chint CJ20 Contactor
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the heart.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...