HH52P HH54P General Purpose Relay HH52P HH54P General Purpose Relay
  • Home
  • Products
    QOD2F 2 Space Flush Load Center

    Automation & Control

    QOD2F 2 Space Flush Load Center

    Circuit Breaker & Fuses

    QOD2F 2 Space Flush Load Center

    Din-Rail Mounted Products

    QOD2F 2 Space Flush Load Center

    Distribution Box & Cabinet

    QOD2F 2 Space Flush Load Center

    Load Center & Meter Bases

    QOD2F 2 Space Flush Load Center

    Solar PV Products

    QOD2F 2 Space Flush Load Center

    Electrical Accessories

    QOD2F 2 Space Flush Load Center

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
HH52P HH54P General Purpose Relay HH52P HH54P General Purpose Relay
Search
HH52P HH54P General Purpose Relay
Click to enlarge
Home Automation & Control Relays HH52P HH54P General Purpose Relay
100A/125A Single Phase Circuit Breaker Panel Load Center
100A/125A Single Phase Circuit Breaker Panel Load Center
Back to products
HT Waterproof Distribution Box
HT Waterproof Distribution Box

HH52P HH54P General Purpose Relay

Size:Miniature
Brand Name:Newtrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:HH52P HH54P JQX-13FZ
Contact Load:High Power
Protect Feature:Sealed
Rated Current:12A
Contact Form:SPST-NO SPST-NC SPDT 2PDT 4PDT
SKU: 1770410312231559168 Category: Relays
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

12A 2NO 4NO 2NC 4NC 2CO 4CO Changeover SPDT DPDT HH52P HH54P JQX-13FZ General Purpose Relay with Test Key and Status Indicator 

 

Model JQX-13FZ-2C (HH52P) JQX-13FZ-4C (HH54P)
Picture    
Dimension 27.3mm*21mm*36.5mm 27.3mm*41mm*36.5mm
Contact
Feature
Form 2NO, 2NC, 2 ChangeOver 4NO, 4NC, 4 ChangeOver
Rated load 12A
Max switching voltage 240VAC/28VDC
Contact resistance ≤100mΩ
Material Silver Alloy
Electrical life / Mechanical life ≥1*105 / ≥1*107
Operate voltage (23℃) DC:≤75%*Rated voltage, AC:≤80%*Rated voltage
Release voltage (23℃) DC:≥10%*Rated voltage, AC:≥30%*Rated voltage
Maximum voltage (23℃) 110%*Rated voltage
Coil voltage DC6-220V, AC6-380V (Customize allowed)
Coil power DC: 0.9W, AC: 1.2VA
Pick-up time / Release time ≤15ms / ≤10ms
Dielectric strength Between Same-pole contacts 1000VAC/1min(leakage current 1mA)
Between Opposite-pole contacts 1000VAC/1min(leakage current 1mA)
Between contacts and coil 1500VAC/1min(leakage current 1mA)
Insulation resistance ≥100mΩ(500VDC)
Ambient temperature / Ambient humidity -25℃ ~55℃ / 45%-75%RH
Atmospheric pressure 86-106KPa
Shock resistance / Vibration resistance 10G (sinusoidal half-wave pulse: 11ms) / 10-55Hz (double amplitude: 1.5mm)
Installation PCB or Socket with DIN Rail or Screw

 

Equivalent to Phoenix Contact RIFLINE type Plug-in industrial relays:

Order Description Equivalent Phoenix Contact part number & order code
JQX-13FZ 12VDC 2DPT 12A REL-IR2/LDP- 12DC/2X21 2903659
JQX-13FZ 24VDC 2DPT 12A REL-IR2/LDP- 24DC/2X21 2903660
JQX-13FZ 48VDC 2DPT 12A REL-IR2/LDP- 48DC/2X21 2903661
JQX-13FZ 60VDC 2DPT 12A REL-IR2/LDP- 60DC/2X21 2903662
JQX-13FZ 110VDC 2DPT 12A REL-IR2/LDP-110DC/2X21 2903663
JQX-13FZ 24VAC 2DPT 12A REL-IR2/L- 24AC/2X21 2903666
JQX-13FZ 120VAC 2DPT 12A REL-IR2/L-120AC/2X21 2903667
JQX-13FZ 230VAC 2DPT 12A REL-IR2/L-230AC/2X21 2903668
JQX-13FZ 12VDC 4DPT 6A REL-IR4/LDP- 12DC/4X21 2903676
JQX-13FZ 24VDC 4DPT 6A REL-IR4/LDP- 24DC/4X21 2903677
JQX-13FZ 48VDC 4DPT 6A REL-IR4/LDP- 48DC/4X21 2903678
JQX-13FZ 60VDC 4DPT 6A REL-IR4/LDP- 60DC/4X21 2903679
JQX-13FZ 110VDC 4DPT 6A REL-IR4/LDP-110DC/4X21 2903680
JQX-13FZ 24VAC 4DPT 6A REL-IR4/L- 24AC/4X21 2903686
JQX-13FZ 120VAC 4DPT 6A REL-IR4/L-120AC/4X21 2903687
JQX-13FZ 230VAC 4DPT 6A REL-IR4/L-230AC/4X21 2903688
 
Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for HH52P HH54P General Purpose Relay.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

SJ Relay Base Socket (IDEC Equivalent)
SJ Relay Base Socket (IDEC Equivalent)

SJ Relay Base Socket (IDEC Equivalent)

Size:Miniature
Brand Name:NewTrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:SJ1S-05B SJ2S-05B
Contact Load:High Power
Protect Feature:Sealed
AHC 1/2 Channel Weekly Programmable DIN Rail Time Switch

AHC 1/2 Channel Weekly Programmable DIN Rail Time Switch

Type:Mini
Brand Name:Newtrend or OEM
Theory:Digital
Place of Origin:China
Feature:Other
application:Timer Switch
Model Number:AHC812 AHC822 AHC810 AHC811
Operating voltage:220 - 240 VAC 50/60Hz
Switching capacity:16A
Type of contact:Changeover contact
55.32 55.34 Plug-in General Purpose Relay (DPDT/4PDT)

55.32 55.34 Plug-in General Purpose Relay (DPDT/4PDT)

Size:Miniature
Brand Name:Newtrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:55 series
Contact Load:High Power
Protect Feature:Sealed
Contact Configuration:2CO 3CO 4CO
Rated Current:10A 5A
SUL181h Weekly Programmable Time Switch
SUL181h Weekly Programmable Time Switch

SUL181h Weekly Programmable Time Switch

Frequency:50Hz,60Hz
Theory:Electronic
Whether the smart:NO
Brand Name:Newtrend
Application:Industrial Equipment,Home Appliances,security systems,Gardening and Irrigation Systems,Automated Control
Material:abs,copper
Place of Origin:China
Max. Current:16A
Model Number:SUL181h SYN161h
Max. Voltage:240V
IP level:IP41
Channel:1 channel
Program:Daily Program
Operating Voltage:230-240VAC/110VAC/24VDC/12VDC
Type:48 switching segments
Shortest switching time:30 minutes
ON/OFF operation:Permanent ON / Permanent OFF
Certification:CCC, CE
iTL Bi-stable Latching Impulse Relay (16A-32A)
iTL Bi-stable Latching Impulse Relay (16A-32A)

iTL Bi-stable Latching Impulse Relay (16A-32A)

Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:iR
Contact Load:High Power
60.12 60.13 Plug-in Electromagnetic Power Relay with LED
60.12 60.13 Plug-in Electromagnetic Power Relay with LED

60.12 60.13 Plug-in Electromagnetic Power Relay with LED

Size:Miniature
Brand Name:Newtrend or OEM
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:60.12, 60.13
Contact Load:High Power
Protect Feature:Sealed
Rated Current:10A
Contact Configuration:2 Pole, 3 Pole
SRT05-E SRT05-A Relay Socket Base for RFT Relays
SRT05-E SRT05-A Relay Socket Base for RFT Relays

SRT05-E SRT05-A Relay Socket Base for RFT Relays

Size:Miniature
Brand Name:Newtrend or OEM brand
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:SRT05 SRT08
Contact Load:High Power
Protect Feature:Sealed
THC Weekly Programmable DIN Rail LCD Digital Timer Switch
THC Weekly Programmable DIN Rail LCD Digital Timer Switch

THC Weekly Programmable DIN Rail LCD Digital Timer Switch

Type:Mini
Brand Name:GEYA
Theory:Digital
Place of Origin:China
application:Timer Switch
Model Number:THC-15A THC-20A THC-30A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • SRT05-E SRT05-A Relay Socket Base for RFT Relays SRT05-E SRT05-A Relay Socket Base for RFT Relays
  • AHC 1/2 Channel Weekly Programmable DIN Rail Time Switch AHC 1/2 Channel Weekly Programmable DIN Rail Time Switch
  • IDEC equivalent RJ Slim Plug-in Power Relay IDEC equivalent RJ Slim Plug-in Power Relay
  • SUL181d SYN161d 24-Hour Analogue Daily Program Time Switch SUL181d SYN161d 24-Hour Analogue Daily Program Time Switch
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the car.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...