NewTrend · THQP Series · 1/2 inch Module per Pole
Product overview
The NewTrend THQP 1P is a space-saving plug-in thermal-magnetic circuit breaker for residential and light-commercial branch circuits. Its 1/2 inch (12.7 mm) module per pole provides overload protection, short-circuit protection and manual ON/OFF switching.
Available in 15–50A ratings at AC 120/240V, the single-pole breaker is 1/2 inch (12.7 mm) wide. It fits designated THQP half-module positions in matching NewTrend PowerMark load centers.
Key features
- 1/2 inch module per pole: Slim 12.7 mm module width per pole; 1/2 inch overall width for 1P.
- Thermal-magnetic protection: Thermal response to sustained overloads and magnetic response to short circuits.
- 10 kA interrupting capacity: Rated at AC 120/240V.
- Manual switching and reset: Front operating handle with ON, OFF and tripped positions.
- Matching PowerMark range: For load-center positions designed to accept THQP half-module breakers.
Technical selection summary
| Brand | NewTrend |
|---|---|
| Series | THQP |
| Product type | Plug-in thermal-magnetic circuit breaker |
| Number of poles | 1P |
| Rated current | 15, 20, 25, 30, 35, 40, 45, 50A |
| Rated voltage | AC 120/240V |
| Frequency | 50/60 Hz |
| Interrupting capacity | 10 kA at AC 120/240V |
| Panel space | 1/2 inch (12.7 mm) module per pole · 1/2 inch (12.7 mm) overall width |
| Protection | Thermal overload and magnetic short-circuit protection |
| Operation | Manual ON/OFF switching and automatic tripping |
| Mounting | Plug-in busbar connection |
| Matching load centers | NewTrend PowerMark TL / TLM series with THQP provisions |
THQP Series Selection Table
This page offers the 1P models. See the THQP 2P circuit breakers for two-pole applications.
Dimensions — THQP 1P
| Rated Current | Width | Height | Depth |
|---|---|---|---|
| 15–50A | 1/2 inch (12.7 mm) | 83.3 mm | 60.3 mm |
1/2 inch (12.7 mm) module per pole. Approximate overall dimensions: 1/2 inch wide × 3-9/32 inches high × 2-3/8 inches deep.
Installation and operation
Select the rated current to suit the circuit load and conductor rating. Install the breaker only in PowerMark positions designed and marked for THQP half-module breakers; follow the panel wiring diagram and maximum circuit count. Observe the terminal markings and tightening instructions. After a trip, clear the fault, move the handle fully to OFF, then switch to ON. Installation and servicing should be carried out by qualified personnel with the supply isolated.
Typical applications
- Residential lighting and socket branch circuits.
- Branch-circuit protection in PowerMark load centers with THQP half-module provisions.
- Light-commercial AC distribution panels.








