NewTrend · THQL Series · Full-Size Plug-In Circuit Breaker
Product overview
The NewTrend THQL 3P is a full-size three-pole plug-in thermal-magnetic circuit breaker for residential and light-commercial distribution. It combines overload protection, short-circuit protection and manual ON/OFF switching.
Rated currents: 15A, 20A, 25A, 30A, 35A, 40A, 45A, 50A, 60A, 70A, 80A, 90A, 100A at AC 240V. The 76.2 mm-wide breaker occupies three full-size panel spaces. It installs onto the busbar in matching NewTrend PowerMark TL / TLM load centers.
Key features
- Full-size three-pole design: 76.2 mm nominal width with a plug-in busbar connection.
- Thermal-magnetic protection: Thermal response to sustained overloads and magnetic response to short circuits.
- 10 kA interrupting capacity: Rated at AC 240V.
- Manual switching and reset: Front operating handle with ON, OFF and tripped positions.
- Matching distribution range: For NewTrend PowerMark TL / TLM load centers.
Technical selection summary
| Brand | NewTrend |
|---|---|
| Series | THQL |
| Product type | Plug-in thermal-magnetic circuit breaker |
| Number of poles | 3P |
| Rated current | 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100A |
| Rated voltage | AC 240V |
| Frequency | 50/60 Hz |
| Interrupting capacity | 10 kA at AC 240V |
| Panel space | Three full-size panel spaces · 76.2 mm nominal width |
| Protection | Thermal overload and magnetic short-circuit protection |
| Operation | Manual ON/OFF switching and automatic tripping |
| Mounting | Plug-in busbar connection |
| Matching load centers | NewTrend PowerMark TL / TLM series |
THQL Series Selection Table
This page offers 3P models in 15A, 20A, 25A, 30A, 35A, 40A, 45A, 50A, 60A, 70A, 80A, 90A, 100A.
Dimensions — THQL 3P
| Poles | Nominal Width | Panel Spaces |
|---|---|---|
| 3P | 76.2 mm | 3 full-size spaces |
Full-size THQL mounting uses a 1-inch (25.4 mm) module per pole.
Installation and operation
Select the rated current to suit the circuit load and conductor rating. Use the matching NewTrend PowerMark TL or TLM load center and follow the terminal markings and tightening instructions. After a trip, locate and clear the fault, move the handle fully to OFF, then switch to ON. Installation and servicing should be carried out by qualified personnel with the supply isolated.
Use the 3P breaker with a matching three-phase PowerMark load center and busbar arrangement.
Typical applications
- Residential lighting and socket branch circuits.
- Branch-circuit protection in NewTrend PowerMark TL / TLM load centers.
- Light-commercial AC distribution panels.