NewTrend · temperature control relay
Product overview
NewTrend RW8-02 controls temperature using an NTC probe. Separate TH and TL controls set the upper and lower temperature thresholds from -15 to +45°C, with adjustable 0.5-5°C hysteresis. It uses its own upper/lower temperature function diagram. The 18mm DIN-rail relay detects a shorted or disconnected sensor circuit, uses AC/DC 24-240V and provides one normally open output rated 16A AC-1.
Technical selection summary
| Model | RW8-02 |
|---|---|
| Function | Upper/lower temperature-range control |
| Sensor type | NTC temperature probe |
| Sensor terminals | T1-T2 |
| Control supply | AC/DC 24-240V, 50/60Hz or DC |
| Supply terminals | A1-A2 |
| Power input | Maximum 2VA |
| Supply tolerance | -15% to +10% |
| Temperature setting range | -15 to +45°C |
| Temperature controls | Separate upper TH and lower TL controls |
| Hysteresis | Adjustable 0.5-5°C |
| Measurement accuracy | ±2°C |
| Sensor-circuit monitoring | Short circuit or sensor disconnection |
| Supply indication | Green LED |
| Output contacts | 1 SPST; 1 normally open contact |
| Output terminals | 11-14 |
| Contact rating | 16A, AC-1 |
| Switching voltage | 250VAC / 24VDC |
| Minimum DC breaking power | 500mW |
| Output indication | Red LED |
| Mechanical life | 10,000,000 operations |
| Electrical life (AC-1) | 100,000 operations |
| Operating temperature | -20 to +55°C |
| Storage temperature | -35 to +75°C |
| Mounting | DIN rail to EN/IEC 60715; 18mm module |
| Protection | IP40 front panel / IP20 terminals |
| Operating position | Any |
| Overvoltage category / pollution degree | III / 2 |
| Maximum conductor size | Solid: 1 x 2.5mm² or 2 x 1.5mm²; with sleeve: 1 x 2.5mm² |
| Body dimensions | 90 x 18 x 64mm |
| Overall height in drawing | 95mm including rail-clip projection |
| Weight | 62g |
| Referenced standard | EN 60255-1 |
Operation
- Connect the NTC probe to T1-T2 and the control supply to A1-A2.
- Set the upper TH and lower TL thresholds separately and adjust hysteresis. Follow the dedicated RW8-02 diagram for the output response at both thresholds.
- The output uses terminals11-14. The green LED indicates supply and the red LED indicates relay-output state.
Typical applications
- Switchboard and enclosure temperature monitoring
- Heating or cooling control using a compatible NTC probe
- Temperature supervision for equipment, radiators and liquid systems with an appropriate probe
View or download RW8-01/02 NTC temperature-control catalogue (PDF)
Product reference images and drawings
Original PTC specifications and model comparison
Original memory/reset timing, wiring, motor application and dimensions
Connect a compatible NTC probe to T1-T2 and follow the exact-model function diagram. The 11-14 output is one normally open contact. Confirm probe specification and supply scope with the order; the sensor drawing illustrates a 50mm x 5mm probe with a 500mm lead. Installation and wiring must be performed by qualified electricians.