NewTrend · plug-in voltage protection
Product overview
The OVS-16Z is a plug-in AC voltage protector with a digital voltage display. It disconnects the connected load when voltage leaves the configured limits, then reconnects after voltage recovery and the selected delay. Choose the matching EU, AU or UK plug/outlet version. The unit provides voltage measurement and voltage protection; it does not measure current or provide an adjustable overcurrent-protection setting.
Technical selection summary
| Model | OVS-16Z |
|---|---|
| Plug / outlet versions | EU, AU and UK, as illustrated |
| Supply / voltage measurement | 100–300 V AC |
| Device current rating | 16 A, non-adjustable; respect the fitted plug/socket and supply-circuit ratings |
| Power marking | 3000 W |
| Functions | Live voltage display, overvoltage/undervoltage disconnection, automatic recovery and voltage calibration |
| Current measurement / adjustable overcurrent protection | Not provided |
| Overvoltage trip setting U1 | 100–300 V; default 270 V |
| Overvoltage recovery setting U2 | 95–295 V |
| Overvoltage recovery delay U3 | 1–500 s; default 30 s |
| Overvoltage action time U4 | 0.1–30 s; default 1 s |
| Undervoltage trip setting U5 | 80–210 V in the illustrated programming sequence |
| Undervoltage recovery setting U6 | 85–215 V in the illustrated programming sequence |
| Undervoltage recovery delay U7 | 1–500 s; default 30 s |
| Undervoltage action time U8 | 0.1–30 s; default 1 s |
| Voltage calibration U9 | −9.5% to +9.5% |
| Power-on delay P1 | 1–500 s; default 10 s |
| Self-consumption | Less than 2 W |
| Switching life | 100,000 operations |
| EU version dimensions | 122 × 55 × 90 mm including plug; case depth 41 mm |
| Controls | SET, up and down keys; output status indicator |
Plug and outlet selection
The EU version uses the illustrated round-pin rear plug and round outlet with earth contacts. The AU version has angled flat pins and the matching three-slot outlet. The UK version has the illustrated rectangular three-pin plug and outlet. Match both sides to the installation and appliance connection.
Voltage protection and automatic recovery
The display shows the measured supply voltage. Overvoltage and undervoltage settings determine when the output disconnects. Separate action delays and recovery delays allow the output to respond after the selected condition persists and to reconnect after an appropriate waiting period. Set a suitable recovery threshold within the normal operating voltage window of the connected equipment.
The power-on delay is adjustable from 1 to 500 seconds. Voltage calibration allows an adjustment from −9.5% to +9.5%. The output indicator shows the switching state.
SET menu and programming sequence
Press SET to move from the voltage display into the sequence: P1 power-on delay; U1 overvoltage trip; U2 overvoltage recovery; U3 overvoltage recovery delay; U4 overvoltage action time; U5 undervoltage trip; U6 undervoltage recovery; U7 undervoltage recovery delay; U8 undervoltage action time; U9 voltage calibration; End. Use the up/down keys to change the active setting and SET at End to exit.
The displayed OFF state is the manual output-switch state shown in the operating sequence. Select the protection and delay settings appropriate to the connected equipment before leaving the installation in service.
Housing and installation dimensions
The EU drawing shows a height of 122mm, width of 55mm and overall depth of 90mm including the plug. The main case depth is 41mm; the rear plug section is shown as 37mm, with an 18mm pin projection. Allow space around the case for access to the controls and ventilation. The PC housing and rear contact construction are illustrated in the product views.
Typical applications
- Local voltage indication and automatic voltage cutoff for compatible household appliances.
- Delayed reconnection after an abnormal supply voltage recovers.
- Plug-in protection for equipment within the voltage, power and connection ratings.
Installation and load limits
Use a compatible, correctly earthed indoor outlet. Keep the connected load within the ratings of the protector, fitted plug/socket and supply circuit. Keep the device dry, provide ventilation and configure voltage limits for the appliance. Provide the required overcurrent and residual-current protection separately in the installation.