NewTrend · four-outlet voltage and current protection
Product overview
The OSVA-16LM combines a four-outlet extension strip with voltage/current indication and adjustable overvoltage, undervoltage and overcurrent protection. It disconnects the shared output during an abnormal condition and supports delayed automatic recovery. Select the EU plug with four EU outlets or the UK plug with four universal-pattern outlets. The current setting applies to the total connected load across the strip.
Technical selection summary
| Model | OSVA-16LM |
|---|---|
| Outlet configurations | EU plug with four EU outlets; UK plug with four universal-pattern outlets |
| Supply | 140–300 V AC, 50/60 Hz |
| Adjustable total current limit | 1–16 A; default 16 A; total across all four outlets |
| Display | Voltage and current indication; power and alarm lamps |
| Overvoltage trip / recovery | 230–300 V / 225–295 V; defaults 270 V / 265 V |
| Overvoltage action / recovery delay | 0.1–30 s / 1–500 s; defaults 0.5 s / 30 s |
| Undervoltage trip / recovery | 140–210 V / 145–215 V; defaults 170 V / 175 V |
| Undervoltage action / recovery delay | 0.1–30 s / 1–500 s; defaults 0.5 s / 30 s |
| Overcurrent action / recovery delay | 0.1–30 s / 1–500 s; defaults 1 s / 30 s |
| Power-on delay | 1–500 s; default 10 s |
| Voltage calibration | −9.5% to +9.5% |
| Current calibration | −9.5% to +9.5% in the programming menu |
| Repeated overcurrent event count | OFF or 1–20 |
| Self-consumption | Less than 2 W |
| Electrical / mechanical life | At least 100,000 operations |
| Cable | H05VV-F, 3 × 1.5 mm² copper conductors |
| Cable length / total assembly length | 1.35 m / approximately 1.6 m |
| EU strip dimensions | 278 × 56 × 42 mm |
| Service functions | Last-fault review and factory reset |
Display, status lamps and keys
The digital display alternates between voltage and current indication. Separate POWER, >V, <V and >A indicators identify the powered state and the three protection conditions. The front keys provide manual output switching, SET menu access, increase and decrease controls. Hold SET for three seconds to enter the setting interface.
Overvoltage, undervoltage and overcurrent response
Set the trip threshold, recovery threshold and delays for the connected equipment. Overvoltage and undervoltage action times are adjustable from 0.1 to 30 seconds. Overcurrent protection uses a 1–16A total-current setting with an independently adjustable action delay and recovery delay. The fault display alternates the alarm code with the associated measured value.
Programming sequence
The menu follows A1 power-on delay; A2 overvoltage trip; A3 overvoltage recovery; A4 overvoltage recovery delay; A5 overvoltage action; A6 undervoltage trip; A7 undervoltage recovery; A8 undervoltage recovery delay; A9 undervoltage action; A10 overcurrent trip; A11 overcurrent recovery delay; A12 overcurrent action; A13 voltage calibration; A14 repeated overcurrent event count; A15 current calibration; End.
Use the up/down keys to adjust the selected value. Press SET at End to exit, or hold SET during adjustment to save. The OFF options at the voltage-threshold extremes disable the corresponding voltage-protection function. The repeated overcurrent setting can be OFF or 1–20 events.
Fault review, reset and manual switching
Hold the up key for more than 12 seconds to review the last fault. To restore factory settings, hold the down key for more than 12 seconds. The manual power key controls the shared output; the OFF state is shown on the display. Review the protection settings after a reset before reconnecting loads.
Cable and plug configurations
The cable is marked H05VV-F with three 1.5mm² copper conductors. Cable length is 1.35m and total assembly length is approximately 1.6m. The EU version uses the illustrated round-pin earthed plug. The UK version uses the illustrated rectangular three-pin plug. Match the selected plug and outlet contacts to the supply and appliance.
Dimensions and installation
The illustrated EU strip measures 278mm long, 56mm wide and 42mm thick. Position the strip so the display and controls remain accessible. Keep it dry and ventilated, and avoid mechanical strain at the cable and plug.
Typical applications and load limits
The strip provides shared voltage/current monitoring and delayed reconnection for compatible household and equipment loads. Keep the combined load within the selected current limit and the ratings of the fitted plug, outlets and supply circuit. All four outlets share the available current; the 16A setting is not a separate allowance per outlet. Provide the required upstream circuit and residual-current protection.