NewTrend · DIN-rail DC energy monitoring
Product overview
The ODCM-63 is a DIN-rail mounted, four-in-one DC multi-function meter. Its colour LCD simultaneously displays DC voltage, current, power and accumulated energy. The instrument measures DC 14–600 V and up to 63 A, and is powered directly from the circuit being measured, without a separate auxiliary supply.
It is suitable for indoor solar-PV monitoring panels, battery systems and industrial DC circuits within the stated measuring ranges.
Technical selection summary
| Model | ODCM-63 |
|---|---|
| Meter type | 4-in-1 DC voltage, current, power and energy meter |
| Voltage measuring range | DC 14–600 V; display 14.0–600.0 V |
| Current measuring range | DC 0–63 A; display 0.00–63.00 A |
| Power measuring range | 0–37,800 W |
| Power display | 0.00–9999.9 W below 10,000 W; integer display from 10,000 to 37,800 W |
| Energy measuring range | 0–999,999 kWh, with automatic decimal position |
| Energy display resolution | 3 decimals below 1,000 kWh; 2 decimals from 1,000 to 9,999 kWh; 1 decimal from 10,000 to 99,999 kWh; integer display from 100,000 kWh |
| Accuracy | 1% |
| Operating supply | Self-powered from the measured DC 14–600 V circuit |
| Display | Full-view colour LCD; simultaneous V, A, W and kWh readings |
| Data retention | Energy saved on power loss; accumulation resumes when power returns |
| Energy reset | Hold the front-panel RESET button for 5 seconds |
| Source terminals | Top IN terminals: positive (+) and negative (−) |
| Load terminals | Bottom OUT terminals: positive (+) and negative (−) |
| Installation | 35 mm DIN rail; indoor use |
| Outline dimensions | 54 × 82 × 66 mm (W × H × D), according to the dimension drawing |
| Other mounting dimensions | 45 mm front-body height; 18 mm + 48 mm depth sections |
Display, energy memory and reset
The display keeps voltage, current, instantaneous power and energy visible together. Energy readings use an automatic decimal position as the accumulated value increases. On a power interruption the meter saves the accumulated energy, then resumes counting from that value when DC power returns. Press and hold RESET for five seconds to clear the accumulated energy.
DC input and load wiring
Connect the DC source to the upper IN terminals and the load to the lower OUT terminals. Positive (+) is on the left and negative (−) on the right in the front-view wiring diagram. Observe polarity, isolate the DC supply before connection and keep the circuit within the meter’s voltage and current ranges. This instrument is intended for DC measurement.
DIN-rail mounting and dimensions
The rear clip attaches to a 35 mm DIN rail. The dimension drawing shows a 54 mm width, 82 mm overall height and 66 mm depth. It also identifies a 45 mm front-body height and depth sections of 18 mm and 48 mm. Install indoors in a suitable panel, leaving space for the connected conductors.
Typical applications
- DC voltage, current, power and energy monitoring in solar-PV panels.
- Battery and energy-storage system monitoring within DC 14–600 V and 63 A.
- Indoor industrial DC power distribution and compatible DC equipment.