NewTrend · manual transfer switch (MTS)
Product overview
The O419G is a four-pole, 80 A manual transfer switch for moving one load between two supplies — normally an inverter, a generator or a standby feed on one side and the city mains on the other. Four poles means three phases plus neutral are switched together, so a single-phase load taken from the same changeover point cannot be left tied to a neutral that still belongs to the source you have just disconnected. All four poles move on one shaft under one handle, and the mechanical interlock keeps the two incoming supplies apart.
The handle has three stable positions: I, centre OFF and II. In the centre position the moving contacts are clear of both sets of fixed contacts, so every pole is isolated from either source and the break is visible at the handle. Because the interlock is mechanical rather than electrical, closing one path physically prevents the other from closing — a control-circuit fault, a welded contactor upstream or two operators working at once cannot put both supplies on the load.
Four-pole changeover in three handle positions
The front of the device carries a printed changeover diagram for each pole, with the terminal numbers of the two sources and the load. In position I the handle connects terminal 1 to 2, 5 to 6, 9 to 10 and 13 to 14. In position II it connects 1 to 4, 5 to 8, 9 to 12 and 13 to 16. In the middle position all eight paths are open.
The four poles are ganged on a common shaft, so it is not possible to operate one pole and leave the others behind — the arrangement that matters when a neutral is being switched alongside the phases. The 80 A rating applies to the whole device, not to a single pole, and the utilisation category marked on the front is AC-22A, which covers mixed resistive and inductive load switching of the kind found on distribution boards, pump panels and small machine supplies.
Technical data
The values below are the ones printed on the device and on the manufacturer’s reference drawings for this model. Rated voltage is marked 400 V~ AC; the changeover is a four-pole device intended for three-phase systems with a switched neutral, so check the marking against the installation before commissioning.
| Model | O419G |
|---|---|
| Product type | Manual transfer switch (MTS), dual-power changeover, disconnectable |
| Poles | 4P (three phases + neutral) |
| Rated current | 80 A |
| Rated voltage | 400 V AC (device marking 400 V~) |
| Frequency | 50/60 Hz |
| Utilization category | AC-22A |
| Contact form | 1-0-2, three positions (I / OFF / II) |
| Insulation voltage (Ui) | 690 V |
| Standards | IEC/EN 60947-3, GB/T 14048.3 |
| Mounting | 35 mm DIN rail (EN 60715), spring clip with screwdriver release |
| Terminals | 1, 3, 5, 7, 9, 11, 13, 15 at the top; 2, 4, 6, 8, 10, 12, 14, 16 at the bottom |
| Width | 72 mm (four 18 mm modules) |
| Housing | Thermoset moulding, self-extinguishing |
Handle, housing and mounting
The operating handle is wider and deeper than a miniature-breaker lever and is ribbed along its length, which gives a firmer grip for the changeover stroke and a clear visual indication of the selected position. The four poles are driven from the same shaft, so the handle position always describes the state of every pole at once.
The body is moulded from a thermosetting plastic rather than a thermoplastic. Thermosets cure into a cross-linked structure and do not soften, flow or drip when the terminals run hot, so the housing keeps its shape and its mechanical strength at temperatures that would deform an ordinary thermoplastic enclosure. That matters at the cable lug, which is where heat concentrates in a transfer switch carrying 80 A continuously.
Installation uses the standard 35 mm rail: the device clips on with the spring-loaded foot at the bottom and is released with a screwdriver in the slot, so it can be fitted or removed without disturbing the modules on either side. Four module widths keep a four-pole changeover point inside a small part of the enclosure, and the side profile stays flat enough to butt directly against adjacent devices.
Wiring
Terminal numbering follows the device: 1, 3, 5, 7, 9, 11, 13, 15 along the top and 2, 4, 6, 8, 10, 12, 14, 16 along the bottom, with the odd numbers on the line side of each pole and the even numbers on the load side. Each pole therefore has one terminal on the line side and a pair on the load side, one for each source.
For dual-power changeover the manufacturer specifies feeding the normal supply and the standby supply from the lower terminals and taking the load from the upper terminals, which is the arrangement drawn on the front face. With the handle at I the load is fed from the normal supply; at II it is fed from the standby supply; at OFF both paths are open and the load is isolated. The incoming and outgoing side can otherwise be arranged to suit the panel, as long as the source and the load are never swapped between the two changeover paths — when the switch is used for dual-power changeover the lower-in, upper-out arrangement must be kept.
Markings on the front face
The front carries the terminal numbers for both rows, the changeover diagram beside the handle, the model and current rating, the rated voltage and frequency, the CE mark and the standard references. The specification block on the lower half repeats the utilisation category AC-22A, the insulation voltage Ui 690 V and the standard numbers, together with the I – O – II symbol, so the ratings can be read with the device already installed in a panel and the enclosure closed.
Typical applications
- Manual changeover between the city mains and a three-phase inverter or generator, with the neutral switched alongside the phases.
- Isolation and source selection on distribution and control panels feeding three-phase loads with a neutral.
- Load transfer where a visible, lockable disconnect position is required.
- Pumping, ventilation, compressors and small three-phase machines that must not be fed from two sources at once.
- Peak-valley tariff switching and PV self-consumption systems with a grid back-up path.
- Marine, mobile and temporary installations where a switched neutral is required by the wiring rules.