GLZ1 Manual Changeover Switch for Generator 100A-1600A GLZ1 Manual Changeover Switch for Generator 100A-1600A
  • Home
  • Products
    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Automation & Control

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Circuit Breaker & Fuses

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Din-Rail Mounted Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Distribution Box & Cabinet

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Load Center & Meter Bases

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Solar PV Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Electrical Accessories

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
GLZ1 Manual Changeover Switch for Generator 100A-1600A GLZ1 Manual Changeover Switch for Generator 100A-1600A
Search
GLZ1 Manual Changeover Switch for Generator 100A-1600A
Click to enlarge
Home Circuit Breaker & Fuses Manual Changeover Switch GLZ1 Manual Changeover Switch for Generator 100A-1600A
SW84 100A SPDT Changeover EV DC Contactor
SW84 100A SPDT Changeover EV DC Contactor
Back to products
Compact S 3P/4P Molded Case Circuit Breaker 125A-1600A
Compact S 3P/4P Molded Case Circuit Breaker 125A-1600A

GLZ1 Manual Changeover Switch for Generator 100A-1600A

Whether the smart:NO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Max. Current:3150A
Province:Zhejiang
Model Number:GLZ1
Max. Voltage:690V
Poles:3P, 4P
Operational handle position:inside Cabinet, outside Cabinet
Certification:CE
SKU: 1770408565916311552 Category: Manual Changeover Switch
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Manual Transfer Switch GLZ1 3P 4P 100A 160A 200A 250A 315A 400A 630A 1000A 1250A 1600A Manual Changeover Switch for Generator

   

Application:

     GLZ1 Manual Change Over Switch is suitable for the changeover of two sets of low voltage electric circuit or the changeover of 2 sets of on-load devices or safety insulation.

     Mode of operation:
     – Handle is operated inside the cabinet
     – Handle is operated outside the cabinet
Products with observation windows can be provided according to the demand to observe directly the on and off state of contact.
The products have 3 poles, 4 poles, and (3 poles + on and off netural pole).
Extended shaft is used for the operation outside the board.
Two sets of auxiliary contacts can be assembled according to the demand.
Mechanical property and electric property correspond to the mechanical property and electric property of GLZ1. A bridge can provided to connect the inlet or outlet terminal of the switch. Note: The bridge connection is chosen, an explanation is needed to indicate the inlet or outlet is connected with it.

 

 

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for GLZ1 Manual Changeover Switch for Generator 100A-1600A.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Voltage & Load Sizing

How to verify rated operational voltage, frequency, and load duty cycle?

A

Verify that the nominal line voltage (AC 230V single-phase or 400V/415V/690V three-phase at 50/60Hz, or DC voltage ratings) falls within the continuous maximum operating limits of the device. Check duty cycle ratings (continuous vs intermittent duty) to ensure thermal stability under full load.

Protection & Environment

What ingress protection (IP Rating) and environmental enclosures are recommended?

A

For clean indoor electrical rooms, standard IP20 modular DIN-rail housings are recommended. For outdoor, industrial washdown, or dusty environments, mount components inside weatherproof enclosures rated IP65/IP66 with UV-resistant polycarbonate or powder-coated steel enclosures equipped with compression cable glands.

Selectivity & Grading

How to ensure upstream and downstream coordination in power distribution boards?

A

Ensure proper discrimination by grading current thresholds and tripping time delays: upstream devices should have higher current ratings and intentional short-time delays (Class S), allowing downstream branch MCBs to clear localized faults without blacking out the entire facility.

Installation & Mounting

What mounting rails, busbars, and spatial clearances are required?

A

Components mount on standard symmetrical 35mm DIN rail (EN 60715 / TH35-7.5) or backplate screw fixings. Maintain recommended top/bottom ventilation gaps (typically 30–50mm) to ensure unrestricted air convection, and use standard pin/fork comb busbars to minimize contact resistance and wiring errors.

Conductor & Torque Sizing

What conductor sizes and terminal tightening torques should be applied?

A

Select copper or aluminum conductor cross-sections complying with IEC 60364-5-52 current-carrying capacity tables based on continuous load. Always use a calibrated torque screwdriver or torque wrench to tighten terminal screws to the manufacturer-specified torque to prevent hot-spot degradation and loose connections.

Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the car.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...