NewTrend · DC contactor
Product overview
The NewTrend NFG150A is a normally open DC relay with a rated control capacity of 150 A at 450 V DC-1. It uses a continuous-duty DC coil with 12 V, 24 V options. Switching life depends on the exact load current and circuit voltage.
Technical selection summary
| Contactor Model | NFG150A |
|---|---|
| Rated Control Capacity | 150A at 450V DC-1 |
| Coil Voltage | DC12V / DC24V |
| Contacts | 1NO |
| Contact Operating Voltage Range | 12~1000 V DC; see load-life conditions |
Electrical and mechanical performance
| Main contact form | One normal open |
|---|---|
| Operating voltage of contact (V (DC)) | 12~1000 |
| Rated control capacity | 150A 450V(DC-1) |
| Rated short-time withstand current and duration | 150A 1200s |
| Additional short-time withstand condition | 400A 300S |
| contact voltage drop (mV) | ≤80@ 100A current |
| Action time (including contact bounce) (ms) | ≤25 |
| release time (ms) | ≤12 |
| Contact bounce time (ms) | ≤6 |
| Maximum breaking current (only one interruption) | 1500A;100V |
| Electrical endurance under varying load conditions (non-polarized, purely resistive load) (time) | 150A, 450V / 5000 times |
| Additional load-life condition | 150A, 750V / 1500 times |
| Additional load-life condition | 150A, 1000V / 1000 times |
| Auxiliary contact (Optional) (Contact form) | / / One normal open |
| Contact load rating | 2A/30V (DC), 3A/125V (AC) |
| Minimum contact load | 100mA/8V |
| insulation resistance (MΩ) | 100 (under the condition of 500V (DC)) |
| Withstand Voltage (V (AC)) | 3500V (AC) 50 Hz/60 Hz (leakage current ≤1mA) 1000V (AC) 50Hz/60Hz (between auxiliary contacts) |
| Operating Temperature (℃) | -40~+85 |
| Operating Humidity | 5%~90%RH |
| altitude (m) | 4000 |
| Impact, 11ms, 1/2 sine wave, peak value (G) | 20 |
| Vibration, sine wave, 80~2000Hz, peak value (G) | 20 |
| Rated duty | Continuous working duty |
| Weight (approximately) (g) | 380 |
| Installation method | arbitrary |
| Coil operating voltage (V (DC)) | 12 / 24 |
| Maximum coil voltage (V (DC)) | 36 / 36 |
| Maximum surge current of coil (A) | 3.8 / 3.8 |
| Maximum surge time (ms) | ≤110 / ≤110 |
| Coil maintenance power (W) | ≤5.0 / ≤5.0 |
| Pickup voltage (V (DC)) | ≤9 / ≤9 |
| Release voltage (V (DC)) | ≤7 / ≤7 |
| Coil polarity | Red wire (positive pole), black wire (negative pole) |
Typical applications
- Battery supply switching for industrial electric vehicles and forklifts
- Electric winches and battery-powered material-handling equipment
- DC auxiliary supply and industrial machinery power circuits