NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
  • Home
  • Products
    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Automation & Control

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Circuit Breaker & Fuses

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Din-Rail Mounted Products

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Distribution Box & Cabinet

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Load Center & Meter Bases

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Solar PV Products

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Electrical Accessories

    People Electric RDB88 Explosion-Proof Induction Lamp, 40–150W

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
Search
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
Click to enlarge
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
Home Solar PV Products DC Isolator Switch NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC
NewTrend DTS238-4-M Three-Phase LCD Energy Meter, 100A, 4-Module
NewTrend DTS238-4-M Three-Phase LCD Energy Meter, 100A, 4-Module
Back to products
NewTrend DDS238-4 W Energy Meter & Timer Protector, 60A, Optional RS485
NewTrend DDS238-4 W Energy Meter & Timer Protector, 60A, Optional RS485

NewTrend H-250-2P PV DC Isolator, 125–250A, 1000–1500V DC


You save

Two-pole non-polar PV DC isolator. IEC60947-3: 125–250 A at 1000 /1500 V DC; UL98B: 250 A at 1500 V DC. Standard-specific short-time ratings, enclosure clearances and complete installation diagrams included.

Model
Poles
Rated Current
Rated Voltage
Standard
Add to Enquiry
SKU: H-250-2P-IEC-UL Categories: Solar PV Products, DC Isolator Switch Brand: NewTrend
  • Description
  • Catalog
Description

NewTrend · Two-Pole PV DC Isolation

Product overview

H-250-2P is a non-polar load-break isolating switch for one PV DC string or circuit. The confirmed two-pole offering covers 125–250 A at 1000 V or 1500 V DC under IEC60947-3, and the separately documented 250 A, 1500 V DC UL98B configuration. Standard-specific short-circuit and endurance values are shown separately below.

Key features

  • Compact, modular two-pole construction for installation inside solar inverters and other DC equipment.
  • Non-polar switching, a lockable operator and low power loss.
  • Arc-extinguishing chamber technology; 10 kA for 50 ms test reference, distinct from the standard-specific Icw values.
  • 10000 mechanical operations.
  • IP20 terminal protection and IP66 external operator/panel assembly.
  • Complete wiring, accessory, enclosure, handle cutout and dimension drawings in the original six-printed-page document.

Confirmed configurations

StandardPolesVoltageRated current
IEC60947-32P1000 V / 1500 V DC125 A / 160 A / 200 A / 250 A
UL98B2P1500 V DC250 A

Use the exact selected standard, voltage and current. The directly linked document illustrates one PV string and one pole in series per conductor path. Follow its complete two-pole wiring diagram.

Standard-specific electrical characteristics

ParameterIEC60947-3UL98B
Operational voltage (Ue)1000 V / 1500 V DC1500 V DC
Offered operational currents125 / 160 / 200 / 250 A250 A
Conventional free-air thermal current (Ith)250 A250 A
Impulse withstand voltage (Uimp)12 kV12 kV
Short-time withstand current (Icw)8 kA for 1 s10 kA for 50 ms
Short-circuit making capacity (Icm)10 kA10 kA for 50 ms
Contact resistanceLess than 0.5 mΩLess than 0.5 mΩ
Utilization categoryDC-PV2Not specified in the document
Electrical cycles in this offered current scope200400
Mechanical cycles1000010000

Original family references and offered scope

Product-page familyH-250
Offered two-pole modelH-250-2P
Product-page pole references2P / 3P / 4P; the current seven factory photographs and the complete direct document cover 2P
Product-page current references80 A / 100 A / 125 A / 160 A / 200 A / 250 A; this offering is the directly documented 125–250 A two-pole scope
Product-page circuit references2P: one 1000 V string; 3P: one 1500 V string; 4P: two 1000 V strings. Additional pole-version supply applicability: To be confirmed.
Product-page standardsIEC60947.3 / AS60947.3; the direct document separately details IEC60947-3 and UL98B
Lower-current family electrical-life referenceAt or below 100 A: 300 cycles, as stated on the family product page; these lower-current variants are not selectable here
Protection referencesIP20 switch body / terminals; IP66 enclosure or external operator according to the specified assembly
PolarityNon-polar
Certification and supplied markingsSource references TUV and other factory certification marks; supplied-product applicability: To be confirmed

Mounting, environment and connections

MountingBase screws
M5 mounting torque2.0–3.0 N·m
M8 wiring torque10–15 N·m, IEC60947-1 reference
Operating ambient−40 °C to +80 °C
Storage temperature−40 °C to +85 °C
Relative humidity90%
Pollution degree3
Terminal protectionIP20
External operator / panel protectionIP66 when assembled as documented
Conductor materialCopper conductor or equivalent copper busbar
125 A conductor section50 mm²
160 A conductor section70 mm²
200 A conductor section95 mm²
250 A conductor section120 mm²

Before energization, verify that every connection, including bridging links, is suitable for the rated current, only conductive parts are clamped, and all connections are tightened to the required torque.

Temperature and altitude references

Ambient−40 °C to +55 °C+60 °C+65 °C+70 °C+75 °C+80 °C
Maximum current250 A250 A250 A250 A250 A250 A
Altitude2000 m3000 m4000 m5000 m
Power-frequency withstand voltage3820 V DC3820 V DC3820 V DC3820 V DC
Isolation voltage1500 V DC1500 V DC1500 V DC1500 V DC
Working current250 A250 A250 A250 A
Working voltageN/A in the sourceN/A in the sourceN/A in the sourceN/A in the source

The altitude table does not state operational voltage. High-altitude operational-voltage applicability: To be confirmed; the isolation-voltage row is not an operational-voltage approval.

Structure and accessory references

Document assembly referencesH-250-2P and H-250-2P-A: front operation; H-250-2P-B: side operation
Offered assembly scopeStandard current product-page configuration; optional assembly suffix correspondence: To be confirmed
Standard shaft length182 mm total; minimum total length 80 mm
Shaft customization reference27–300 mm in the complete dimension drawings
Standard accessory listHandle, coupling square shaft, interphase barrier, M8 binding kits and specification/manual
Optional accessory referencesAuxiliary contact and custom shaft length
Auxiliary-contact suffixAX; exact supplied contact specification and compatibility: To be confirmed

UL98B enclosure and operator installation references

Minimum enclosure, H × W × D400 × 350 × 180 mm; UL98B reference
Clearance A, minimum25.4 mm
Clearance B, minimum50.8 mm
Clearance C, minimum22 mm
Panel fixing holes4 × Ø6 ±0.2 mm
Operator cutoutØ32 ±0.2 mm
Fixing-hole centres28 ±0.2 mm and 40 ±0.2 mm
Operator tightening torque2.5 N·m

Complete technical document

Download the complete H-250 two-pole family datasheet (3 wide PDF pages / 6 printed pages)

The complete original layout retains both standard columns, all circuit diagrams, body and operator dimensions, accessory illustrations, enclosure clearances, derating and installation requirements. The first seven gallery images retain the current factory-page angles and order.

Complete overview, type designation and standard-specific parameters

Complete overview, type designation and standard-specific parameters

Two-pole wiring and alternative assembly references

Two-pole wiring and alternative assembly references

Complete accessory illustrations and supply references

Complete accessory illustrations and supply references

UL98B enclosure clearances and operator cutout

UL98B enclosure clearances and operator cutout

Complete standard and alternative body dimensions

Complete standard and alternative body dimensions

Complete derating and conductor installation tables

Complete derating and conductor installation tables
Catalog
NameSizeRelease timeOperate
NewTrend H-250-2P PV DC Isolator.pdf1.86 MB2026-11-22Download

Related products

NewTrend FPV-H2XLB 400A 1500V DC Solar PV Fuse Base
NewTrend FPV-H2XLB 400A 1500V DC Solar PV Fuse Base

NewTrend FPV-H2XLB 400A 1500V DC Solar PV Fuse Base

FPV-H2XLB 400A 1500V DC photovoltaic fuse base for FPV-H2XL fuse links. Spring-loaded blade contacts, bolted terminals and a two-hole mounting base. Original outline drawing, dimensions and a two-page NewTrend PDF included.

NewTrend FPV-63T 1500V DC 50A Solar Fuse Holder, 10x85 / 14x85mm
NewTrend FPV-63T 1500V DC 50A Solar Fuse Holder, 10x85 / 14x85mm

NewTrend FPV-63T 1500V DC 50A Solar Fuse Holder, 10×85 / 14x85mm

1500V DC, 50A photovoltaic fuse holder for 10 × 85mm and 14 × 85mm fuse links. 35mm DIN-rail mounting with optional fuse-operation indicator.

NewTrend UD-S1500 Type 1+2 DC Surge Protective Device, 1500V DC
NewTrend UD-S1500 Type 1+2 DC Surge Protective Device, 1500V DC

NewTrend UD-S1500 Type 1+2 DC Surge Protective Device, 1500V DC

UD-S1500 is a combined Type 1+2 DC surge protective device for 1500V photovoltaic circuits. Thermal disconnection provides green/red operating and fault indication. The unit mounts on a 35mm DIN rail, with optional remote status signalling.

NewTrend FPV-32L 10x85mm 20A gPV Solar Fuse Link, 1500V DC
NewTrend FPV-32L 10x85mm 20A gPV Solar Fuse Link, 1500V DC

NewTrend FPV-32L 10x85mm 20A gPV Solar Fuse Link, 1500V DC

10x85mm 20A gPV cylindrical solar fuse link. 20kA at 1500V DC. Ceramic body, copper element and quartz silica filling.

NewTrend FPV-H3L 500A 1500V DC gPV Solar Fuse, 50kA
NewTrend FPV-H3L 500A 1500V DC gPV Solar Fuse, 50kA

NewTrend FPV-H3L 500A 1500V DC gPV Solar Fuse, 50kA

FPV-H3L is a square-body gPV fuse link for photovoltaic DC circuit protection. The exact illustrated unit is marked 500A, 1500V DC, 50kA and IEC 60269-6. Its original dedicated dimensional drawing identifies the same model, including a 205mm overall length and 125mm body length. Complete two-page NewTrend datasheet available.

NewTrend FPV-H00 1000V DC 100A gPV Solar Fuse Link, 50kA
NewTrend FPV-H00 1000V DC 100A gPV Solar Fuse Link, 50kA

NewTrend FPV-H00 1000V DC 100A gPV Solar Fuse Link, 50kA

1000V DC 100A gPV blade-type solar fuse link, 50kA breaking capacity. Ceramic body, copper element, quartz silica filling and IEC 60269-6 marking.

NewTrend FPV-H1XL 1500V DC 160A gPV Solar Fuse Link, 30kA
NewTrend FPV-H1XL 1500V DC 160A gPV Solar Fuse Link, 30kA

NewTrend FPV-H1XL 1500V DC 160A gPV Solar Fuse Link, 30kA

1500V DC 160A gPV blade-type solar fuse link, 30kA breaking capacity. Ceramic body, copper element, quartz silica filling and IEC 60269-6 marking.

NewTrend FPV2258B 1500V DC 80A Solar Fuse Holder, 22x58mm
NewTrend FPV2258B 1500V DC 80A Solar Fuse Holder, 22x58mm

NewTrend FPV2258B 1500V DC 80A Solar Fuse Holder, 22x58mm

1500V DC photovoltaic fuse holder, rated up to 80A, for 22 × 58mm fuse links. 35mm DIN-rail mounting, standard locking design and optional fuse-operation indicator.

Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
    • AFDD & RCBO
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
    • Power Quality
      • Terminal Power Quality Regulators
      • Automatic Voltage Conditioners
      • Advanced Static Var Generators
      • Active Harmonic Filters
      • Static Var Generators
    • Rotary Encoders
    • Switching Power Supplies
    • Communication Gateways
    • PID Temperature Controllers
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
    • Digital Timer Switches
    • Mechanical Timer Switches
    • DIN Rail Signal Indicators
    • Overcurrent Protectors
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • Plastic Junction Box
    • Aluminum Junction Box
    • Optical Fiber Boxes
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • TYE Load Center
    • Meter Bases
    • Steel Junction Box
    • Safety Switches
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
    • Solar Cables
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Din Rail
    • Meter & Transformer
    • Wiring Accessories
      • Waterproof Connectors
      • Cable Glands
      • Busbars
      • Quick-Disconnect Terminals
      • Quick-Splice Connectors
      • IEC Power Entry Modules
    • EV Charging Accessories
    • Smart Sockets & Plug-in Protectors
    • Others
      • ABB Electrical Materials
        • ABB MCCB
        • ABB Contactor
        • ABB MCB
        • ABB Motor Protection
        • ABB Overload Relay
        • ABB RCCB
        • ABB RCBO
        • ABB UL MCCB
        • ABB Switch Disconnector
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
      • People Electrical Materials
        • People MCB
        • People RCCB RCBO
        • People MCCB ACB
          • People Air Circuit Breakers
          • People Moulded Case Circuit Breakers
        • People Contactor & Overload Relays
        • People Relays
        • People Fuse & Disconnectors
        • People Inverter & Soft Starters
        • People Pushbutton & Pilot Lights
        • People Changeover Switches
        • People Capacitor & Reactors
        • People Voltage Stabilizers
        • People New Energy
        • People Motor Drive Protection
        • People Master Switches
        • People Control Transformers
        • People Rectifiers & Thyristors
        • People Industrial Plugs & Sockets
        • People Terminal Blocks
        • People Electromagnets
        • People Bells & Alarms
        • People Low Voltage Switchgear
        • People High Voltage Switchgear
        • People Other Equipment
        • People Power Transformers
          • People Dry Type Transformers
          • People Oil Immersed Transformers
          • People Combination Transformers & Substations
        • People Hazardous Area Equipment
          • People Explosion-Proof Fans
          • People Industrial & Hazardous Area Lighting
          • People Explosion-Proof Electrical Apparatus
          • People Explosion-Proof Conduit & Fittings
          • People Dust Explosion-Proof Equipment
          • People Plastic Explosion-Proof Equipment
        • People Energy Meters
        • People Measuring Instruments
        • People Cables & Conductors
      • Noark Electrical Materials
        • Noark UL ACB
        • Noark UL MCCB
        • Noark UL MCB
        • Noark UL RCCB
        • Noark UL Enclosed Breakers
        • Noark UL Contactor & Overload Relays
        • Noark UL Inverter & Soft Starters
        • Noark UL Motor Protection & Manual Starters
        • Noark UL Fuse & Disconnectors
        • Noark UL Surge Protection Devices
        • Noark UL DC Circuit Breakers & Disconnectors
      • CNC Electrical Materials
        • CNC Smart Circuit Breakers
        • CNC DC Contactors
        • CNC MCCB
        • CNC PV Combiner Boxes
        • CNC DC Circuit Breakers
        • CNC Surge Protection Devices
        • CNC Modular Contactors
        • CNC Soft Starters
        • CNC AC Contactors
        • CNC DC Isolators
        • CNC Rotary Changeover Switches
        • CNC Voltage Protection Relays
        • CNC Automatic Transfer Switches
        • CNC RCBO
        • CNC MCB
        • CNC Manual Changeover Switches
        • CNC Time Relays
        • CNC PV Fuse Holders
        • CNC Motor Protection
        • CNC RCCB
        • CNC Time Switches
        • CNC Liquid Level Relays
        • CNC Thermal Overload Relays
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
    • CHINT Ordering Codes
      • NXB-63 Codes
      • NM8N Codes
      • NB1-63 Codes
      • NC1 Codes
      • NC2 Codes
      • NXC Codes
      • NL1-63 Codes
      • NB1L Codes
      • NA1 Codes
      • NB1-63H Codes
      • NXB-125 Codes
      • NB2LE Codes
      • NXBLE-125 Codes
      • NB1-63DC Codes
      • NL210 Codes
YOU MAY ALSO LIKE…
  • CHINT 101243 NA1-3200X-2500H 3P 2500A Drawout Motorized ACB CHINT 101243 NA1-3200X-2500H 3P 2500A Drawout Motorized ACB
  • CHINT 102371 NA1-2000X-1000H 3P 1000A Fixed Motorized ACB CHINT 102371 NA1-2000X-1000H 3P 1000A Fixed Motorized ACB
  • CHINT 101082 NA1-2000X-1250M 3P 1250A Fixed Motorized ACB CHINT 101082 NA1-2000X-1250M 3P 1250A Fixed Motorized ACB
  • CHINT 101103 NA1-4000X-4000M 3P 4000A Drawout Motorized ACB CHINT 101103 NA1-4000X-4000M 3P 4000A Drawout Motorized ACB
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar

    Sending...

    Get a quotation 0

    SHANGHAI NEWTREND ELECTRIC

    Get a quotation

    Review your products. Send one request for everything.

    Your products 0 items

    You can send a general enquiry, or add products to this list.

    Product removed.

    Add products

    Browse all products →

    Your contact details

    We use your details to respond to this enquiry. Privacy policy