NewTrend · PV DC Surge Protection
Product overview
UD-1500 is a Type 2 DC surge protective device for 1500V photovoltaic circuits. Thermal disconnection provides green/red operating and fault indication. The unit mounts on a 35mm DIN rail, with optional remote status signalling.
Key features
- Type 2 protection for 1500V photovoltaic DC systems.
- Three plug-in high-energy MOV modules.
- 40kA maximum and 20kA nominal discharge current at 8/20μs.
- Thermal fault indication and optional remote contact.
Technical selection summary
Product identity
| Model | UD-1500 |
|---|---|
| SPD classification | Type 2 (T2) |
| Test standard | IEC/EN 61643-31; product-page edition IEC/EN 61643-31:2018 |
| Number of ports | 1 |
Electrical performance
| Maximum open-circuit PV voltage Uoc max | 1500V DC |
|---|---|
| Maximum PV operating voltage Ucpv | 1500V DC |
| Short-circuit current rating Iscpv | 10kA |
| Maximum discharge current Imax, 8/20μs (DC+/DC− → PE) | 40kA |
| Total discharge current Itotal, 8/20μs | 40kA |
| Nominal discharge current In, 8/20μs (DC+/DC− → PE) | 20kA |
| Voltage protection level Up | ≤5.5kV |
| Response time tA | ≤25ns |
| Individual plug-in module Ucpv / Up | 750V DC / 2.7kV; complete-device values are 1500V DC / ≤5.5kV |
Indication and construction
| Operating / fault indication | Green / Red |
|---|---|
| Fault indication mechanism | Internal thermal disconnect |
| Remote status signalling | Optional changeover contact; full ordering code to be confirmed |
| Protection module construction | Three plug-in high-energy MOV modules; base and replaceable modules |
Connection and installation
| Minimum conductor cross-section | 1.5mm² solid / flexible |
|---|---|
| Maximum conductor cross-section | 35mm² stranded / 25mm² flexible |
| Mounting rail | TH35-7.5 / DIN35; 35mm DIN rail |
| Installation location | Indoor installation |
| Degree of protection | IP20 |
| Operating temperature | −40°C to +80°C |
| Outline dimensions (W × H × D) | 74 × 94.5 × 83mm |
| Drawing reference dimensions | 88.5mm body height; 45mm body depth; 55.5mm depth reference; 5.5mm rail-side reference |
Documentation for supplied marking
| TUV / CE applicability | To be confirmed for the supplied product marking |
|---|
Certification documents must match the supplied product marking. Complete-device ratings and individual plug-in module ratings are listed separately.
Typical applications
Overvoltage protection of photovoltaic DC circuits and associated PV inverter or controller cabinets, within the specified voltage and discharge-current ratings.
Download the complete UD-1500 technical datasheet
UD-1500 principal drawing and dimensions
Applicable to the UD-1500 base version. Dimensions in mm.