NewTrend · arc-fault and residual-current protection
Product overview
The OB6L-63H combines an arc fault detection device with residual-current, overload and short-circuit protection for 1P+N or 2P, 230V AC final circuits. Current options run from 10A to 63A with a C characteristic and 30mA Type AC residual-current protection. The 1P+N housing is 35mm wide and the 2P housing is 53mm wide. Both mount on a standard 35mm DIN rail.
Technical selection summary
| Model | OB6L-63H |
|---|---|
| Product function | Combined AFDD and RCBO |
| Pole arrangement | 1P+N / 2P |
| Rated voltage / frequency | 230V AC, 50/60Hz |
| Rated-current options | 10A / 16A / 20A / 25A / 32A / 40A / 50A / 63A |
| Trip characteristic | C curve |
| Rated residual operating current | 30mA |
| Residual-current type | Type AC |
| Rated short-circuit breaking capacity | 6000A |
| Residual making / breaking marking | IΔm = 2000A |
| Residual-response marking | t ≤0.1s |
| Protection functions | Arc fault, residual current, overload and short circuit |
| Standard references | IEC 61009 / IEC 62606; IEC 61009-1 marked on the illustrated unit |
| Electrical endurance | At least 6000 operations |
| Mechanical endurance | At least 20000 operations |
| Mounting | 35mm DIN rail |
| Dimensions | 1P+N: 35mm wide; 2P: 53mm wide; both 100mm high, 66mm case depth / 74mm overall depth |
| Front section reference | 1P+N: 45mm; 2P: 50mm; see the matching drawing |
| Operating controls | Blue switching handle, green RST reset button and orange test / AFDD-setting button |
| Status indication | Mechanical contact-state window and separate status light |
Combined protection functions
The arc-fault function monitors circuit waveforms to identify dangerous arcing associated with damaged conductors, loose connections, crushed cords or ageing insulation. It distinguishes these conditions from normal operating arcing in switches, motor brushes and similar loads. The combined device also provides C-curve overcurrent protection and 30mA Type AC residual-current protection.
Front controls and reset
The blue handle switches the circuit. The green RST button resets the protection mechanism after operation; identify and clear the fault before resetting and restoring the handle. The orange button is marked for a short test press and a five-second AFDD-setting press. The separate state light and contact-position window provide operating indications. Follow the supplied operating instructions for testing and setting procedures.
Contact-state indication
The illustrated handle-down position indicates the circuit is off, while the handle-up position indicates it is on. The mechanical window changes with contact position. The separate status light belongs to the electronic protection functions; do not use an indicator alone to verify safe electrical isolation.
Line and load connections
Use the upper terminals marked Power for the incoming supply and the lower terminals marked Load for the outgoing circuit. The illustrated 1P+N version has L on the left and N on the right. The illustrated 2P version has N on the left and L on the right. Follow the L/N marks and the diagram for the selected version; do not transfer the left-to-right order from one version to the other. Installation and conductor preparation should be carried out by a qualified person with the supply isolated and terminals securely tightened.
1P+N connection arrangement
2P connection arrangement
The two-pole version uses the N-left / L-right terminal arrangement shown below.
1P+N dimensions and DIN-rail installation
The 1P+N outline is 35mm wide and 100mm high. The side view shows a 66mm case-depth reference and 74mm overall depth, with a 45mm front-section reference and 35mm DIN-rail mounting. Leave clearance for the upper and lower conductors, terminal access and the rail-release mechanism.
2P dimensions
The 2P outline is 53mm wide and 100mm high, with a 66mm case-depth reference and 74mm overall depth. Its front-section reference is 50mm. Use the matching mounting outline and terminal order for this wider version.
Typical applications
For compatible single-phase final circuits in residential, commercial and equipment distribution boards where combined arc-fault, residual-current and overcurrent protection is required. Select the rated current for the conductor and connected load, and coordinate the device with the complete installation and upstream protection.