DELIXI ELECTRIC · H500
Product overview
DELIXI H500 provides general-duty and light-load motor drive ratings. The documented original English selection scope is retained with exact pairedG/P power and current.
Technical selection summary
| Input / output | Three-phase AC380–480V, 50/60Hz input; three-phase 0–input-voltage output; maximum 599Hz |
|---|---|
| Power / current | G/P values are paired per construction; 0.4–37kW G and 0.75–45kW P. Select by actual motor current and load duty |
| Braking / reactor | 0.4–15kW G:built-in braking unit and no DC reactor.18.5–37kW G:DC reactor standard, braking unit optional. Buttons use the no-built-in-brake base for those larger models |
| Overload | G/heavy-duty150% for 60s; P/light-load120% for 60s in the current English manual |
| Keyboard / options | Base standard LED keyboard with potentiometer; LCD, communication and encoder extensions are separate options. No arbitrary safety or keyboard suffix is added |
| Drawings / wiring | Original English catalogue plus current English manual selection, dimensions, power/control wiring and terminal descriptions retained |
| Source discrepancy | The15kW G /18R5 P construction is omitted from selectable rows because the current manual prints18kW in the paired power cell. No correction is guessed. |
The slash separates the same drive’sG/P duty ratings. Optional built-in braking for 18.5kW and above requires its exactB construction. A braking unit does not include a correctly sized external resistor.
Typical applications
- DELIXI H500 provides general-duty and light-load motor drive ratings.