NewTrend · DC182
Product overview
NewTrend DC182-style200A motor-reversing contactors for battery-driven machinery. Select DC coil voltage independently of the DC48V contact-circuit limit.
Technical selection summary
| Parameter | Specification |
|---|---|
| Construction | Monoblock motor-reversing changeover contactor;NewTrend/OEM Albright-reference style |
| Main circuit | Continuous200A;DC≤48V in exact supplier table. No unqualified80V switching claim |
| Coil | DC12/24/36/48/72V;36V stated in original product text, otherlisted values in exact table;≤20W |
| Timing / duty | Pickup≤50ms;release≤50ms;continuous duty |
| Voltage drop / making | Contact drop≤100mV;momentary closing7Ie for≤1s |
| Environment / protection | IP50;-25 to+55°C;altitude≤2000m |
| Dimensions / connection | Full outline retained;main studM8;match actual motor wiring and supplied circuit diagram |
| Resistance reference | 12V7.2Ω;24V28.8Ω;48V115.2Ω;60V180Ω;72V259.2Ω;80V320Ω at20°C±10%;a resistance row alone is not a new selectable supply commitment |
This is NewTrend replacement supply,not original Albright. Specific JLG part numbers are not treated as universal equivalents. Verify contact arrangement,mounting and actual equipment wiring before ordering;the source table rather than the old generic6-80V description governs the main-circuit limit.
Typical applications
- Battery-vehicle motor reversing
Open technical reference image