QX4A Automatic Star Delta Reduced Voltage Motor Starter QX4A Automatic Star Delta Reduced Voltage Motor Starter
  • Home
  • Products
    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Automation & Control

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Circuit Breaker & Fuses

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Din-Rail Mounted Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Distribution Box & Cabinet

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Load Center & Meter Bases

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Solar PV Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Electrical Accessories

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
QX4A Automatic Star Delta Reduced Voltage Motor Starter QX4A Automatic Star Delta Reduced Voltage Motor Starter
Search
QX4A Automatic Star Delta Reduced Voltage Motor Starter
Click to enlarge
Home Automation & Control Motor Manual Starters QX4A Automatic Star Delta Reduced Voltage Motor Starter
ELR-3C Earth Leakage Relay
ELR-3C Earth Leakage Relay
Back to products
Auto Recloser RCCB RCBO 2P/4P 25A-63A Smart RCD
Auto Recloser RCCB RCBO 2P/4P 25A-63A Smart RCD

QX4A Automatic Star Delta Reduced Voltage Motor Starter

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:QX4A
SKU: 1770409057375494144 Category: Motor Manual Starters
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

QX4A automatic Ac induction motor starter 220V 380V 500V ANP YS YD YX YX3 YEJ YVP YCCL Y motor Y2 motor Star Delta Starter

 

Starter model

Max starting induction motor (KW)

220V

380V

500V

QX4A-1/H

4KW

7.5KW

7.5KW

QX4A-2/H

7.5KW

13KW

13KW

QX4A-3/H

17KW

30KW

30KW

QX4A-4/H

30KW

55KW

55KW

 

 

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for QX4A Automatic Star Delta Reduced Voltage Motor Starter.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

Sold out
3VE1 DZ108 Manual Motor Protection Circuit Breaker

3VE1 DZ108 Manual Motor Protection Circuit Breaker

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:3VE1
Phase:3
Main Circuit Rating Current:0.1A ~ 20A
Type:Moulded Case
Sold out
LC3-D TeSys Automatic Star Delta Motor Starter

LC3-D TeSys Automatic Star Delta Motor Starter

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC3-D
Phase:3
Main Circuit Rating Current:9A ~ 95A
Sold out
3RV1 Manual Motor Starter Protector Circuit Breaker
3RV1 Manual Motor Starter Protector Circuit Breaker

3RV1 Manual Motor Starter Protector Circuit Breaker

Rated Frequency:50/60hz
Type:Motor Manual Starter
BCD Curve:C
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:3RV1
Poles Number:3
Breaking Capacity:10kA
LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter
LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter

LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:QCX2 (LE1-D)
Electricity Type:AC
Sold out
3VU Motor Protector Circuit Breaker

3VU Motor Protector Circuit Breaker

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:3VU1300 3VU1600
Breaking Capacity:20kA
Rated Voltage:380V
Type:Moulded Case
LE1D 3-Phase DOL Magnetic Motor Starter
LE1D 3-Phase DOL Magnetic Motor Starter

LE1D 3-Phase DOL Magnetic Motor Starter

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LE1D
Electricity Type:AC
GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker
GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker

GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker

Rated Frequency:50/60hz
Type:Motor Manual Starter
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:GV2ME GV3ME GV2P GV3P
Poles Number:3
Breaking Capacity:16kA
Sold out
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME

GV2MC IP55 Enclosure Box for GV2ME

Rated Frequency:50/60hz
Type:Moulded Case
BCD Curve:C
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:GV2ME
Poles Number:3
Breaking Capacity:16kA
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter
  • 3VU Motor Protector Circuit Breaker 3VU Motor Protector Circuit Breaker
  • GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker
  • 3VE1 DZ108 Manual Motor Protection Circuit Breaker 3VE1 DZ108 Manual Motor Protection Circuit Breaker
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the house.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...