LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
Search
LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
Click to enlarge
Home Electrical Accessories Others LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
LW26-80 Star-Delta O-Y-Delta Motor Starter Changeover Switch
LW26-80 Star-Delta O-Y-Delta Motor Starter Changeover Switch
Back to products
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch

LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch

Brand Name:Newtrend or OEM brand
Place of Origin:China
Max. Current:25A 32A 63A
Model Number:LW26 -** 0-Y-D
Max. Voltage:690V
Certification:CE
SKU: 1770408299582201856 Category: Others
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

LW26 25A 32A 63A 3 position Switching on Star Delta OYD Motor starter switch Manual change over control Rotary Cam Switch

 

Rotary switches LW26 series

The rotary switches LW26 series are produced for switching on/off electrical circuits with commutated current from
20 to 160A. They are designed on the bases of the rotor-eccentric switching on which is realized through turning
of the handle to 60 or 90 degrees. The normal operation is used for commutation of two, three or four conductor
systems. There are special rotary switches that switch on under given connection schemes and are used to
control motors, electric welding machines and other consumers.

Documentation corresponding to the product:
Standard: EN 60947-1; EN 60947-3-1

Technical data:
* Power supply voltage: 230/400V; 50Hz
* Insulation voltage: 690V
* Impulse voltage wear resistance: 6000V
* Mechanical wear resistance: 3×105 commutation cycles
* Operation temperature: -10 ~ +50 ℃
* Humidity: 35 – 85% RH
* Commuting capacity: up to 160A according to the tables
* Plastic: UV rays wear resistance
* IP code:
– IP42 for the ordinary breakers mounted in a panel
– IP65 for the breakers offered in a box
* Cable connection: screw joining
* Tightening moment of the bolt: 1.33N
* Maximum section of the power supply conductors: according to the dimensions table
* Weight: according to the number of the contacts
Mounting:
* directly to the control panel
* thickness of the surface to which it is mounted: max 5mm

 

Model

Characteristics

Current Available

Positions

LW26 -** 0-1-2-3

Acts with selectivity up to 3 different circuits, single-phase operation

20/25/32/63

4 (0-1-2-3)

LW26 -** 0-1-2-3-4

Acts with selectivity in up to 4 different circuits, single-phase operation

20/25/32/63

5 (0-1-2-3-4)

LW26 -** 0-Y-D

Used for 3 position switching, O-star-delta, motor starter switch

25/32/63

3 (0-Y-D)

LW26 -** 6S/4

Used for two speed motor control; switching over between charging

25/32/63

3 (1-0-2)

LW26 -** YH3/3

Used for line meters in three-phase systems

20

4 (0-RS-ST-TR)

LW26 -** YH5/3

Used for voltage switching over

20

7 (TR-ST-RS-0-

RN-SN-TN)

LW26 -** LH3/3

Used for amperemeter switching on to current transformers

20

4 (0-R-S-T)

LW26 -** 6N/3

Used for phase inversion / rotation in three-phase system

20/32/63/125/160

3 (1-0-2)

LW26 -** 6Q/2

Used for three-poles switching on; motor starting and stopping; voltage on/off

20/32/63/125/160

2 (0-1)

LW26 -** D0081/1

Transfer switch (switching) monopolar

125/160

3 (1-0-2)

LW26 -** D0723/3

Transfer switch (switching) tripolar

125/160

3 (1-0-2)

LW26 -** D1050/4

Transfer switch (switching) tetrapolar

125/160

3 (1-0-2)

 

Description

LW26-20

LW26-25

LW26-32

LW26-63

LW26-125

LW26-160

Thermal Current (Ith)

20 A

25 A

32 A

63 A

125 A

160 A

Working Voltage (Ue)

240V

440V

240V

440V

240V

440V

240V

440V

240V

440V

240V

440V

Working Current (Ie)

A

AC21/AC22

20

25

32

63

100

150

AC23

15

22

30

57

90

135

AC2

15

22

30

57

90

135

AC3

11

15

22

36

75

95

AC4

3,5

6,5

11

15

30

55

AC15

5

4

8

5

14

6

***

***

***

Power

kW

AC23

3,7/2,5

7,5/3,7

5,5/3

11/5,5

7,5/4

15/7,5

15/10

30/18,5

30/15

45/22

37/22

75/37

AC2

4

7,5

5,5

11

7,5

15

18,5

30

30

45

37

55

AC3

3/2,2

5,5/3

4/3

7,5/3,7

5,5/4

11/5,5

11/6

18,5/11

15/7,5

30/13

22/11

37/18,5

AC4

0,55/0,75

1,5/1,5

1,5/1,1

3/2,2

2,7/1,5

5,5/3

5,5/2,4

7,5/4

6/3

12/5,5

10/4

15/7,5

 

 

Model

Front Plate

A

B

C

E

F

L

D1

D2

LW26-20

Square

48

48

43

36

36

22+9.6n

Φ8.5

Φ4.5

LW26-20*

Retangular

48

60

43

36

36

22+9.6n

Φ8.5

Φ4.5

LW26-25

Square

48

48

45

36

36

23+12.8n

Φ8.5

Φ4.5

LW26-32

Square

64

64

58

48

48

29.2+12.8n

Φ10

Φ4.5

LW26-63

Square

64

64

66

48

48

29.2+21.5n

Φ10

Φ4.5

LW26-125

Square

88

88

84

68

68

35+26.5n

Φ13

Φ6

LW26-160

Square

88

88

88

68

68

35+32.5n

Φ13

Φ6

* n = number of modules

 

 

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

750V-1000V High Voltage Automotive EV Contactor 50A-400A
750V-1000V High Voltage Automotive EV Contactor 50A-400A

750V-1000V High Voltage Automotive EV Contactor 50A-400A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC66P
Phase:1
Main Circuit Rating Current:200A
600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A
600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A

600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A
LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A

LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker
THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker

THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:220V,230V,240V,120V
LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor
LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor

LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K09
Phase:3
Main Circuit Rating Current:9A
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K LP1K
Phase:3
Main Circuit Rating Current:6A 9A 12A 16A
type:Magnetic contactor
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • LC1D09 3P 9A AC Contactor 24VDC/220V/230V/240V LC1D09 3P 9A AC Contactor 24VDC/220V/230V/240V
  • CHINT Ex9ASD-DC Solar PV Air Switch Disconnector CHINT Ex9ASD-DC Solar PV Air Switch Disconnector
  • CHINT NB1Z-63 Low Voltage DC MCB 1P/2P 60V/125V/220V CHINT NB1Z-63 Low Voltage DC MCB 1P/2P 60V/125V/220V
  • DELIXI DZ47PLEY-63 1P+N RCBO 6A-63A 30-300mA Residual Breaker DELIXI DZ47PLEY-63 1P+N RCBO 6A-63A 30-300mA Residual Breaker
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the key.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...