NewTrend / OEM · Miniature contactor for heat-pump control
Product overview
This listing concerns miniature contactors for heat-pump control assemblies. Select the exact contact arrangement, coil type and coil voltage.
Technical selection summary
| Listing / reference model | LC1K / LP1K |
|---|---|
| Product type | Miniature contactor for heat-pump control |
The family motor-power tables use specified voltage and load categories. Do not apply three-phase motor values directly to a single-phase heat pump or compressor. Confirm actual starting current, duty and protection coordination. Confirm screw-clamp, Faston, spring-terminal or PCB-pin construction and its matching outline. Auxiliary blocks, LR2K overload relays, reversing interlocks and star-delta assemblies require a documented compatible combination; motor-power data must match voltage and utilization category.
Product reference images and drawings
Use the matching model and version in the reference data. Confirm the applicable rating, test conditions and dimensions against the exact supplied unit.
| Model Number | LC1K06 | LC1K09 | LC1K12 | LC1K16 | LP1K06 | LP1K09 | LP1K12 | LP1K16 |
| Rated operational current (AC-3, 380V) | 6A | 9A | 12A | 16A | 6A | 9A | 12A | 16A |
| Rated operational current (AC-3, 660V) | 5A | 7.5A | 10A | 12A | 5A | 7.5A | 10A | 12A |
| Coil voltage (Control circuit voltage) | AC 230V 240V 380V 415V | DC 220V 230V 240V 250V | ||||||
| Rated operational voltage | 380V, 660V | |||||||
| Rated insulation voltage | 690V | |||||||
| Main and auxiliary contacts | 3P+NO, 3P+NC, 2NO+2NC | |||||||
| Motor power (AC-3, 220/240V) | 1.5KW | 2.2KW | 3KW | 3KW | 1.5KW | 2.2KW | 3KW | 3KW |
| Motor power (AC-3, 380/415V) | 2.2KW | 4KW | 5.5KW | 7.5KW | 2.2KW | 4KW | 5.5KW | 7.5KW |
| Motor power (AC-3, 440V) | 3KW | 4KW | 5.5KW | 7.5KW | 3KW | 4KW | 5.5KW | 7.5KW |
| Motor power (AC-3, 500/660/690V) | 3KW | 4KW | 4KW | 4KW | 3KW | 4KW | 4KW | 4KW |
| Mouting type | DIN Rail / PCB Solder Pin / Plate | |||||||
| Coil Pull-In Voltage | 0.85-1.1 Us | |||||||
| Coil Drop-Out Voltage | 0.2-0.75 Us | ≤0.2 Us | ||||||
| Coil power | Pull-In 40VA, Maintain 4VA | |||||||
| Coil power consumption | 1.2W | |||||||
| Coil Pull-In time | 6-18 ms | |||||||
| Coil Drop-Out time | 5-12 ms | |||||||
| Electrical life | 500 thousand times | |||||||
| Mechanical life | 100 thousand times | |||||||
| Ambient air temperature | -5…40 °C | |||||||
| Operating altitude | 2000 m without derating in temperature | |||||||
| LC1K (AC voltage coil) | |||||||||||||||||
| Volts (50/60Hz) | 12 | 20 | 24 | 36 | 42 | 48 | 110 | 115 | 120 | 127 | 200/ 208 | 220/ 230 | 230 | 230/ 240 | 256 | 277 | 380/ 400 |
| Code | J7 | Z7 | B7 | C7 | D7 | E7 | F7 | FE7 | G7 | FC7 | L7 | M7 | P7 | U7 | W7 | UE7 | Q7 |
| Volts (50/60Hz) | 400 | 400/ 415 | 440 | 480 | 500 | 575 | 600 | 660/ 690 | |||||||||
| Code | V7 | N7 | R7 | T7 | S7 | SC7 | X7 | Y7 | |||||||||
| LP1K (DC voltage coil) | |||||||||||||||||
| Volts | 12 | 20 | 24 | 36 | 48 | 60 | 72 | 100 | 110 | 125 | 155 | 174 | 200 | 220 | 230 | 240 | 250 |
| Code | JD | ZD | BD | CD | ED | ND | SD | KD | FD | GD | PD | QD | LD | MD | MPD | MUD | UD |
| LP1K09105BD: | |
| LP1K means DC coil contactor, LC1K means AC coil contactor | |
| 09 means AC-3 9A rated current | |
| 10 means NO auxiliary contact, 01 means NC auxiliary contact | |
| 5 means PCB Solder Pin type, without 5 means regular DIN Rail type | |
| BD means the coil voltage code |