NewTrend · Enclosed PV DC Isolation
Product overview
YT-32 is a non-polar PV DC isolating switch in a UV-resistant, flame-retardant IP66 enclosure. It is designed for DC isolation between solar panels and an inverter in residential and commercial rooftop PV systems. The four-contact module supports the documented single-string and double-string wiring arrangements. Operational current depends on standard, wiring and voltage.
Key features
- Up to1200V DC /32A in the confirmed4B IEC arrangement.
- IP66 enclosure and IP20 switch body; maintain watertight cable entries and assembly.
- UV-resistant and flame-retardant enclosure material.
- Arc-extinguishing chamber; source arcing time less than3ms.
- Breathing valve supplied at the enclosure bottom to reduce condensation.
- Earth terminal and OFF-position lockable rotary handle.
- Non-polar connections and documented single/double-string circuit arrangements.
Product specifications
| Model | YT-32 |
|---|---|
| Circuit pole arrangements | 2-pole or 4-pole circuit arrangements; four-contact switch module. Follow the selected wiring diagram. |
| Standards | IEC 60947-3; AS 60947.3:2018 |
| Utilization category | DC-PV2 |
| Product-page operational voltage range | 500V / 600V / 800V / 1000V / 1200V DC; the AS-specific table additionally documents700V and900V configurations |
| Source family operational-current range | 9–40A; the confirmed selectable configurations below cover9A /13A /32A. Additional arrangements: To be confirmed. |
| Mechanical operating cycles | 15000 |
| Electrical operating cycles | 1000 |
| Protection degree | IP66 enclosure / IP20 switch body |
| Polarity | Non-polar; + and − connections may be interchanged as documented |
| Source certificate references | TUV / CB / CE; supplied-marking applicability: To be confirmed |
Electrical characteristics
| Function | Isolator / control |
|---|---|
| Physical contacts | 4 |
| Rated frequency | DC |
| Rated insulation voltage (Ui) | 1200V |
| Conventional free-air thermal current | Not specified in the source table |
| Conventional enclosed thermal current | See the thermal conditions below and the selected configuration |
| Rated conditional short-circuit current (Icc) | 3kA |
| Rated impulse withstand voltage (Uimp) | 8kV |
| Overvoltage category | II |
| Suitable for isolation | Yes |
| Contact distance per pole — AS table | 8mm |
Conditional short-time ratings
For wiring4 and4B, the direct document lists Icw1kA for1s and short-time making current1.7kA. Its2H reference lists Icw1.7kA for1s and short-time making current3kA. Only the configurations below are offered as confirmed selections; the complete family document retains other reference arrangements.
Available voltage, current and wiring combinations
| Standard | Wiring | Operational voltage | Operational current |
|---|---|---|---|
| IEC | 4 | 500V /600V DC | 32A |
| IEC | 4 | 800V DC | 13A |
| IEC | 4 | 1000V /1200V DC | 9A |
| IEC | 4B | 500V /600V /800V /1000V /1200V DC | 32A |
| AS60947.3:2018 | 4 | 500V /600V DC | 32A |
| AS60947.3:2018 | 4 | 700V /800V DC | 13A |
| AS60947.3:2018 | 4 | 900V /1000V /1200V DC | 9A |
| AS60947.3:2018 | 4B | 500V /600V /700V /800V DC | 32A |
Wiring4 is the documented two-string, four-contact arrangement; the source table specifies two poles in series. Wiring4B is the documented single-string arrangement with four poles in series. The actual connections and bridging links must follow the corresponding diagrams. The source family also shows2H and4S arrangements; additional selection details are To be confirmed.
Enclosure thermal conditions
| Dedicated enclosure identification | YT-32 IP66NW; the source identification requires a minimum IP56NW enclosure classification |
|---|---|
| Enclosed rated thermal current at40°C shade ambient | 32A |
| Indoor rated thermal current at40°C shade ambient in the dedicated enclosure | 32A |
| Outdoor rated thermal current at40°C shade ambient without solar effects | 32A |
| Outdoor solar current at60°C shade ambient, with solar effects in the dedicated enclosure | 29A |
Operational switching current and enclosure thermal current are different fields. Apply the stated thermal and solar-exposure conditions when sizing the installed circuit. The enclosure assembly catalogue-number field is not specified in the source identification table.
Terminals and installation environment
| Storage temperature | −50°C to +90°C |
|---|---|
| Operating temperature | −40°C to +85°C |
| Mounting | Vertically or horizontally; waterproof assembly is required for any chosen orientation |
| Pollution degree | 3 |
| Environment | Outdoor / indoor |
| Terminal designation | 1 /3 /5 /7 and2 /4 /6 /8 |
| Terminal type | Screw terminal |
| Rated main-circuit cross-section | 4–16mm² |
| Rigid copper conductor | 4–16mm², solid or stranded |
| Flexible conductor | 4–10mm² |
| Conductors per terminal | 1 |
| Conductor preparation | Required |
| Stripping length | 8mm |
| M4 terminal tightening torque | 1.2–1.8N·m |
Only conductive parts may be clamped. Verify all connections, including bridging links, and tighten them to the required torque before energization. The complete document illustrates both correctly and incorrectly installed bridging links.
Technical figures
The complete document is a family reference that also includes MC4 versions. The product offered here is the base enclosure version, without MC4 leads. Certification applicability and final supply details must be confirmed for the supplied marking.
Overview and electrical parameters
YT-32 base enclosure; MC4 illustration is a separate family reference.
Breathing valve and enclosure thermal data
Source enclosure identification and operational current data.
Wiring configurations and bridging-link installation
Complete family wiring illustrations. Only the confirmed configurations in the selection table are offered.
Terminals, IP protection and dimension reference
The factory dimension illustration identifies YH-32. Dimensional applicability to YT-32: To be confirmed. Other terminal and IP data are the directly supplied family references.
AS60947.3:2018 family reference
Complete original AS reference table. This document includes additional arrangements outside the confirmed selectable scope.