NewTrend · Single-phase contact voltage regulators
Product overview
General application
The TDGC2 and TDGC2J series provide continuously adjustable single-phase AC output for electrical testing, industrial heating and laboratory power control. The TDGC2 models listed here cover 0.2–20 kVA, and the TDGC2J models cover 0.5–30 kVA. Both use a nominal 220 V AC input and a standard 0–250 V AC output range.
Working principle and construction
A rotary handwheel drives a spring-loaded carbon brush across the exposed contact track of a toroidal winding. As the brush moves, it changes the effective turns ratio and adjusts the AC output continuously. The silicon-steel toroidal core and copper winding provide a compact construction with low losses. The graduated dial or front-panel voltmeter indicates the setting, depending on the enclosure. The three gallery images show different series housings. The third image shows the TDGC2-3 marking.
Model designation
TDGC2 series
TDGC2–3
- Series
- TDGC2
- Suffix
- 3 kVA rated capacity
- Range
- 0.2–20 kVA
- Max. output
- 12 A
- Overall size
- 210 × 230 × 235 mm
TDGC2J series
TDGC2J–3
- Series
- TDGC2J
- Suffix
- 3 kVA rated capacity
- Range
- 0.5–30 kVA
- Max. output
- 12 A
- Overall size
- 265 × 270 × 215 mm
Both series have a 220 V AC input and 0–250 V AC adjustable output. TDGC2 covers 0.2–20 kVA; TDGC2J covers 0.5–30 kVA and includes 7 kVA and 30 kVA models. At equal capacity the listed maximum output current is the same, while enclosure dimensions differ. For example, TDGC2-3 and TDGC2J-3 are both 3 kVA / 12 A, with overall dimensions of 210 × 230 × 235 mm and 265 × 270 × 215 mm respectively.

The input and output share a winding. Use a separate isolation transformer where the test setup requires galvanic isolation. Size the regulator for both the load current and apparent power.
Electrical ratings and operating conditions
| Parameter | Specification |
|---|---|
| Phase | Single-phase |
| Rated input | 220 V AC ±10% |
| Output voltage | 0–250 V AC, continuously adjustable |
| Frequency | 50/60 Hz |
| Efficiency | >90% at rated capacity |
| Waveform | No additional waveform distortion from the adjustment method |
| Insulation resistance | ≥5 MΩ at 500 V DC |
| Dielectric strength | 2,000 V AC for 1 min |
| Ambient temperature | −5 to +40 °C |
| Relative humidity | ≤90% at +25 °C, non-condensing |
| Installation altitude | ≤1,000 m |
| Winding temperature rise | <60 °C, resistance method |
Technical selection summary
Standard input and output for the models below are 220 V AC and 0–250 V AC, respectively. All listed models are single-phase.
TDGC2 model selection
| Model | Capacity (kVA) | Max. output (A) | Overall W × D × L (mm) |
|---|---|---|---|
| TDGC2-0.2 | 0.2 | 0.8 | 105 × 130 × 130 |
| TDGC2-0.5 | 0.5 | 2 | 125 × 150 × 130 |
| TDGC2-1 | 1 | 4 | 180 × 200 × 210 |
| TDGC2-2 | 2 | 8 | 180 × 200 × 210 |
| TDGC2-3 | 3 | 12 | 210 × 230 × 235 |
| TDGC2-5 | 5 | 20 | 240 × 285 × 250 |
| TDGC2-10 | 10 | 40 | 240 × 335 × 400 |
| TDGC2-15 | 15 | 60 | 240 × 335 × 560 |
| TDGC2-20 | 20 | 80 | 240 × 340 × 590 |
TDGC2J model selection
| Model | Capacity (kVA) | Max. output (A) | Overall W × D × L (mm) |
|---|---|---|---|
| TDGC2J-0.5 | 0.5 | 2 | 130 × 150 × 160 |
| TDGC2J-1 | 1 | 4 | 185 × 200 × 215 |
| TDGC2J-2 | 2 | 8 | 230 × 240 × 215 |
| TDGC2J-3 | 3 | 12 | 265 × 270 × 215 |
| TDGC2J-5 | 5 | 20 | 350 × 395 × 260 |
| TDGC2J-7 | 7 | 28 | 350 × 390 × 260 |
| TDGC2J-10 | 10 | 40 | 350 × 410 × 420 |
| TDGC2J-15 | 15 | 60 | 350 × 410 × 570 |
| TDGC2J-20 | 20 | 80 | 350 × 410 × 570 |
| TDGC2J-30 | 30 | 120 | 350 × 410 × 1080 |
Packing dimensions and weights
Net and gross weights are given alongside the corresponding carton quantity and dimensions.
TDGC2 packing data
| Model | Units/carton | Carton W × D × L (mm) | Net (kg) | Gross (kg) |
|---|---|---|---|---|
| TDGC2-0.2 | 12 | 380 × 347 × 350 | 25 | 26.5 |
| TDGC2-0.5 | 8 | 380 × 347 × 350 | 27 | 28 |
| TDGC2-1 | 4 | 435 × 255 × 465 | 25 | 26 |
| TDGC2-2 | 4 | 435 × 255 × 465 | 31.5 | 33 |
| TDGC2-3 | 2 | 490 × 275 × 270 | 21.5 | 23 |
| TDGC2-5 | 1 | 330 × 275 × 290 | 17.5 | 18 |
| TDGC2-10 | 1 | 390 × 295 × 505 | 34 | 40 |
| TDGC2-15 | 1 | 390 × 295 × 650 | 50 | 58 |
| TDGC2-20 | 1 | 390 × 295 × 650 | 53 | 60 |
TDGC2J packing data
| Model | Units/carton | Carton W × D × L (mm) | Net (kg) | Gross (kg) |
|---|---|---|---|---|
| TDGC2J-0.5 | 8 | 330 × 295 × 455 | 30 | 31.5 |
| TDGC2J-1 | 4 | 430 × 395 × 275 | 26 | 27.5 |
| TDGC2J-2 | 2 | 460 × 250 × 245 | 18 | 19.5 |
| TDGC2J-3 | 2 | 490 × 280 × 255 | 26 | 27 |
| TDGC2J-5 | 1 | 460 × 430 × 340 | 25 | 29 |
| TDGC2J-7 | 1 | 430 × 430 × 340 | 27 | 30.5 |
| TDGC2J-10 | 1 | 430 × 430 × 500 | 47.5 | 51 |
| TDGC2J-15 | 1 | 430 × 430 × 690 | 67 | 73 |
| TDGC2J-20 | 1 | 430 × 430 × 690 | 80 | 86 |
| TDGC2J-30 | 1 | 440 × 440 × 1170 | 138 | 150 |
Typical applications
- Electrical meter calibration, transformer testing, and contactor pickup and dropout testing.
- Laboratory power control, equipment voltage sweeps, and production test benches.
- Voltage control for resistive heating, sealing, preheating and drying equipment.
- Industrial furnace and process-heating trials, filament lighting control, and compatible AC commutator motor test setups.
Available custom configurations
Factory options include alternate input taps, extended output ranges, copper or copper-clad aluminium windings, and analogue or digital indication. Enclosure options include lifting handles, casters on larger units and custom finishes. The standard ratings above apply to the listed 220 V versions.