NewTrend · intermediate control relay
Product overview
NewTrend R8-316 is a DIN-rail intermediate relay for switching control-circuit loads and multiplying available contacts. It provides 3 spdt rated 16A AC-1, with a maximum changeover time of 40ms and red LED output indication. Choose a separate AC/DC 12V, AC/DC 24V or AC 230V version. All three output changeover contacts use the exact-model terminal arrangement shown in the catalogue. The 18mm DIN-rail body supports compact panel installation.
Technical selection summary
| Model | R8-316 |
|---|---|
| Function | Intermediate control relay / contact multiplication |
| Output contacts | 3 SPDT |
| Contact rating | 16A, AC-1 |
| Output terminals | 11-12-14; 21-22-24; 31-32-34 |
| Discrete AC/DC supply versions | 12V / 24V |
| AC/DC-version supply terminals | A1-A2 |
| AC/DC-version maximum power input | AC 12VA / DC 1.9W |
| 230V-version supply | AC 230V |
| 230V-version supply terminals | A1-A2 only |
| 230V-version maximum power input | AC 6VA |
| Supply tolerance | -15% to +10% |
| Maximum changeover time | 40ms |
| Switching voltage | 250VAC / 24VDC |
| Minimum DC breaking power | 500mW |
| Output indication | Red LED |
| Mechanical life | 10,000,000 operations |
| Electrical life (AC-1) | 100,000 operations |
| Reset time | Maximum 200ms |
| Operating temperature | -20 to +55°C |
| Storage temperature | -35 to +75°C |
| Mounting | DIN rail to EN/IEC 60715; 18mm module |
| Protection | IP40 front panel / IP20 terminals |
| Operating position | Any |
| Overvoltage category / pollution degree | III / 2 |
| Maximum conductor size | Solid: 1 x 2.5mm² or 2 x 1.5mm²; with sleeve: 1 x 2.5mm² |
| Body dimensions | 90 x 18 x 64mm |
| Overall height in drawing | 95mm including rail-clip projection |
| Weight values in factory catalogue | 86g / 96g (version dependent; individual mapping not labelled) |
Operation
- Apply the selected nominal supply to the exact terminals shown for that voltage version. The supply choices are separate versions, not a continuous adjustable-voltage range.
- The red LED indicates output state. The changeover contacts switch the connected control circuits when the relay is operated.
- Use the R8-316 diagrams for the three changeover contacts. Do not apply the A3 arrangement used by other R8 models.
Typical applications
- Contact multiplication in automation and control panels
- Switching control-circuit loads within the stated AC-1 contact rating
- Interface and auxiliary switching in compact DIN-rail installations
View or download R8-116/208/308/316 intermediate relay catalogue (PDF)
Product reference images and drawings
Original model coding, contact comparison and supply-version specifications
Original wiring for every model and voltage version, with dimensions
The product photographs show the AC/DC 12V version; printed voltage markings are retained. Select the supply version before wiring. The R8-316 uses A1-A2 and has no A3 dual-input arrangement. Its three contacts do not change the stated 250VAC/24VDC switching-voltage limit. Installation and wiring must be performed by qualified electricians.