NewTrend / OEM · Machine-tool control transformer
Product overview
The JBK3 tables retain separate capacity, voltage, mounting-dimension and model references.
Technical selection summary
| Listing / reference model | JBK3 series |
|---|---|
| Product type | Machine-tool control transformer |
Specify actual VA, frequency, primary supply, secondary outputs and required load distribution. The dimensional comparison includes frames beyond the title range; select the exact row and drawing. VA is apparent power and must not be treated as an unconditional watt output. Specify VA rating, primary and secondary voltages, frequency, winding/tap arrangement and mounting dimensions. Confirm insulation, temperature rise, altitude and ambient conditions from the exact transformer document.
Product reference images and drawings
Use the matching model and version in the reference data. Confirm the applicable rating, test conditions and dimensions against the exact supplied unit.
| Type | Overall size(mm) | Hole distance for installation (mm) | Installation hole K or K x J(mm) | Fmax (mm) | |||
|---|---|---|---|---|---|---|---|
| Bmax | Dmax | Emax | A | C | |||
| JBK3-40,60 | 78 | 72 | 89 | 56±0.4 | 51±2 | 4.8 × 9 | 12 |
| JBK3-100 | 85 | 85 | 94 | 64±0.4 | 66±2 | 4.8 × 9 | 12 |
| JBK3-160 | 96 | 91 | 109 | 84±0.4 | 73±2 | 5.8 × 11 | 14 |
| JBK3-250 | 96 | 105 | 109 | 84±0.4 | 87±2 | 5.8 × 11 | 14 |
| JBK3-400 | 120 | 109 | 123 | 90±0.4 | 90±2 | 7 × 12 | 18 |
| JBK3-630 | 150 | 112 | 150 | 122±0.5 | 90±2 | 7 × 12 | 22 |
| JBK3-1000 | 160 | 195 | 151 | 126±2 | 152±2 | 7 × 12 | 18 |
| JBK3-1600 | 184 | 220 | 163 | 140±2 | 176±2 | 7 × 12 | 18 |
| JBK3-2500 | 200 | 250 | 171 | 172±2 | 200±2 | 7 × 12 | 18 |
| Type | Rated capacity (VA) | Uel rated input voltage (V) | Rated output voltage | ||
|---|---|---|---|---|---|
| Control | Illumination | Indication | |||
| JBK3-40 | 40 | 220±5% 380±5% | 110 (127) | 24 (36) | 6 (12) |
| JBK3-63 | 63 | ||||
| JBK3-100 | 100 | ||||
| JBK3-160 | 160 | ||||
| JBK3-250 | 250 | ||||
| JBK3-400 | 400 | ||||
| JBK3-630 | 630 | ||||
| JBK3-1000 | 1000 | Distribution of capacity for different winding may be according to the uses’ request. | |||
| JBK3-1600 | 1600 | ||||
| JBK3-2500 | 2500 | ||||