NewTrend · W50
Product overview
NewTrend W50 reversing winch contactor with 50A continuous and supplier-confirmed 250A intermittent current.
Technical selection summary
| Parameter | Specification |
|---|---|
| Continuous current | 50A |
| Intermittent current | 250A, supplier-confirmed; specify duty cycle and switching conditions |
| Main circuit | 6-80V DC; current capacity is not a guaranteed breaking current at every voltage |
| Contacts | Reversing contact arrangement per drawing |
| Coil voltage | DC12V, DC24V |
| Coil power | 25-27W |
| Dielectric strength | AC1000V, 50Hz, 1min |
| Dimensions / mounting | Use the retained dimensional drawing below |
The original 200A intermittent row is superseded by the supplier confirmation of 250A. A permissible on/off duty cycle must be specified with the quotation. Third-party winch compatibility is not guaranteed.
Typical applications
- Electrical panel assembly and installation
Open technical reference image
Main circuit voltage: Max 80V DC for the supplied NewTrend version. Coil voltage is selected separately. Any 48V contact-circuit marking in retained legacy reference drawings describes the earlier reference, not the current supplied rating.