CHINT 252520 NU6-IIG/F 1P+N 65kA 320V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252520: 1P+N, 320 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the phase module at 8/20 µs.

CHINT 252521 NU6-IIG/F 1P+N 65kA 385V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252521: 1P+N, 385 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the phase module at 8/20 µs.

CHINT 252522 NU6-IIG/F 1P+N 65kA 440V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252522: 1P+N, 440 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the phase module at 8/20 µs.

CHINT 368979 NU6-IIG/F 2P 100kA 385V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 368979: 2P, 385 V AC Uc, 100 kA Imax, 50 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252548 NU6-IIG/F 3P 40kA 320V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252548: 3P, 320 V AC Uc, 40 kA Imax, 20 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252549 NU6-IIG/F 3P 40kA 385V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252549: 3P, 385 V AC Uc, 40 kA Imax, 20 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252550 NU6-IIG/F 3P 40kA 440V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252550: 3P, 440 V AC Uc, 40 kA Imax, 20 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252551 NU6-IIG/F 3P 65kA 275V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252551: 3P, 275 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252552 NU6-IIG/F 3P 65kA 320V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252552: 3P, 320 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252553 NU6-IIG/F 3P 65kA 385V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252553: 3P, 385 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 252554 NU6-IIG/F 3P 65kA 440V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 252554: 3P, 440 V AC Uc, 65 kA Imax, 30 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.

CHINT 368981 NU6-IIG/F 3P 100kA 385V Type 2 SPD

Type 2 CHINT surge protective device with removable cartridges. Ordering code 368981: 3P, 385 V AC Uc, 100 kA Imax, 50 kA In, with remote signalling. Discharge-current ratings are for the protective module at 8/20 µs.