NewTrend · Type 1+2 PV DC Surge Protection
Product overview
UD-S1000 is a combined Type 1+2 DC surge protective device for photovoltaic circuits up to 1000V DC between the DC conductors. It uses a voltage-sensitive resistor for rapid surge limitation, with thermal disconnection and green/red status indication. UD-S1000R adds optional remote status signalling.
Key features
- Combined T1+T2 surge protection for solar photovoltaic DC systems.
- 30kA total discharge current at 8/20μs and 12.5kA at 10/350μs.
- 6.25kA lightning impulse current at 10/350μs; 15kA nominal discharge current at 8/20μs.
- Thermal fault indication, optional remote status signalling and 35mm DIN-rail mounting.
Technical selection summary
Product identity
| Model without remote signalling | UD-S1000 |
|---|---|
| Model with remote signalling | UD-S1000R |
| SPD classification | Type 1+2 (T1+T2) |
| Test standard | IEC/EN 61643-31; product-page edition IEC 61643-31:2018 |
| Number of ports | 1 |
Electrical performance
| Maximum PV voltage Ucpv (DC+ → DC−) | ≤1000V DC |
|---|---|
| Maximum PV voltage Ucpv (DC+/DC− → PE) | ≤725V DC |
| Short-circuit current rating Iscpv | 2kA |
| Total discharge current Itotal, 8/20μs (DC+/DC− → PE) | 30kA |
| Total discharge current Itotal, 10/350μs (DC+/DC− → PE) | 12.5kA |
| Nominal discharge current In, 8/20μs | 15kA |
| Lightning impulse current Iimp, 10/350μs (DC+/DC− → PE) | 6.25kA |
| Voltage protection level Up (DC+/DC− → PE) | 2.5kV |
| Voltage protection level Up (DC+ → DC−) | 4.75kV |
| Response time tA | ≤25ns |
Indication and construction
| Operating / fault indication | Green / Red |
|---|---|
| Thermal disconnection | Fault indication by thermal disconnection |
| Remote status signalling | Optional; UD-S1000R |
| Material statement | RoHS material, as specified for the source product |
Connection and installation
| Minimum conductor cross-section | 1.5mm² solid / flexible |
|---|---|
| Maximum conductor cross-section | 35mm² stranded / 25mm² flexible |
| Mounting rail | TH35-7.5 / DIN35; 35mm DIN rail |
| Installation location | Indoor installation |
| Degree of protection | IP20 |
| Operating temperature | −40°C to +80°C |
| Outline dimensions (W × H × D) | 68 × 96 × 71mm |
| Drawing reference dimensions | 92mm body height; 55mm depth reference; 5.5mm rail-side reference |
Documentation and supplied configuration
| TUV / CE documentation for supplied marking | To be confirmed |
|---|---|
| Warranty terms for supplied product | To be confirmed |
Confirm the TUV/CE documentation and warranty terms for the supplied product marking.
Typical applications
- Overvoltage and lightning-surge protection of photovoltaic DC circuits.
- DIN-rail mounted protection in indoor PV electrical assemblies.
Download UD-S1000 technical datasheet (PDF)
Principal drawing

Outline dimensions

Product views