NewTrend · Alternating-load timer relay
Product overview
NewTrend RT6-RL alternates two loads using a common operating interval t1 and a separately adjustable pause interval t2. The right load starts first with S-A1 open; linking S-A1 selects the left load first. Two SPDT outputs operate the separate load-control circuits in an 18mm DIN-rail housing.
Technical selection summary
| Model | RT6-RL |
|---|---|
| Output contacts | 2 SPDT |
| A230 power input | AC maximum 6VA / 1.9W |
| Weight | S240: 67g; A230: 70g |
| Function | Alternating two-load operation with a pause interval |
| Supply terminals | A1-A2 |
| Control supply options | S240: AC/DC 24-240V; A230: AC 230V; 50-60Hz |
| Supply tolerance | -15% to +10% |
| S240 burden | AC 0.7-3VA / DC 0.5-1.7W |
| Supply indication | Green LED |
| Time setting | Independent t1/t2 range selectors and 10%-100% potentiometers |
| Timing scales | 0.1s-100days; independent t1 and t2 |
| Marked time ranges | 1s, 10s, 1min, 10min, 1h, 10h, 1day, 10days, 30days, 100days |
| Time setting deviation | 10% with mechanical adjustment |
| Repeat accuracy | 0.2% of set value |
| Temperature coefficient | 0.05%/degree C at 20 degrees C |
| Contact rating | 10A (AC-1) |
| Switching voltage | 250VAC / 24VDC |
| Minimum DC breaking power | 500mW |
| Output indication | Red LED |
| Mechanical life | 10,000,000 operations |
| Electrical life (AC-1) | 100,000 operations |
| Reset time | Maximum 200ms |
| Operating temperature | -20 to +55 degrees C |
| Storage temperature | -35 to +75 degrees C |
| Mounting | DIN rail to EN/IEC 60715 |
| Protection | IP40 front panel; IP20 terminals |
| Operating position | Any |
| Overvoltage category | III |
| Pollution degree | 2 |
| Maximum conductor size | Solid: 1 x 2.5mm2 or 2 x 1.5mm2; with sleeve: 1 x 2.5mm2 (AWG 12) |
| Terminal tightening torque | 0.4Nm |
| Body dimensions | 90 x 18 x 64mm |
| Referenced standards | EN 61812-1; IEC 60947-5-1 |
Set the common load operating interval t1 and the pause interval t2. Choose the first load with the S-A1 connection. Use appropriate contactors and interlocking for the controlled equipment.
Operation
- With S-A1 open, the right output operates for t1; after the pause t2, the left output operates for the same t1 interval. The sequence then continues alternately.
- Connecting S-A1 reverses which load starts first. Refer to the load-contactor reference circuit for the terminal arrangement.
Typical applications
- Alternating operation of two loads
- Two-contactor sequencing
- Equipment requiring equal operating periods with a pause between loads
Specify your enquiry
For a focused quotation, include:
- Control supply version: AC/DC 24-240V or AC 230V
- Operating interval, pause interval and first-load preference
- Load characteristics, quantity and delivery destination
Download NewTrend RT6-RL datasheet (PDF)
Product reference images and drawings
Terminal connections
Right-first and left-first timing diagrams
RT6-RL housing dimensions.
Two-load contactor reference circuit
Set the common load operating interval t1 and the pause interval t2. Choose the first load with the S-A1 connection. Use appropriate contactors and interlocking for the controlled equipment. Each interval equals its selected range multiplied by its 10%-100% fine adjustment. Installation and wiring must be performed by qualified electricians.