People Electric · Electric Bell
Product overview
People Electric UC4 electric bells use an internal-striking construction and are offered as UC4Z-55, UC4Z-75, UC4Z-100 and UC4Z-150. The manufacturer provides model-specific AC/DC voltage options, bell diameters, sound levels and power ratings.
Technical selection summary
| Manufacturer / series | Original People Electric UC4 / UC4Z |
|---|---|
| UC4Z-55 | 55mm bell; sound level >65dB; 10W; AC3/6/24V or DC6/12/24V |
| UC4Z-75 | 75mm bell; sound level >70dB; 10W; AC24/36/48V or DC6/12/24V |
| UC4Z-100 | 100mm bell; sound level >75dB; 20W; AC110/127V or DC36/48V |
| UC4Z-150 | 150mm bell; sound level >80dB; 20W; AC220/380V or DC110/220V |
| Duty limitation | Maximum continuous working duration: 5 minutes |
| Supply tolerance | Within ±10% of the selected rated voltage |
| Installation environment | Relative humidity <85%; sheltered from rain and snow; avoid corrosive gases and conductive dust |
| AC supply frequency | Specify the installation frequency for confirmation with the ordered AC version |
Select the exact model before choosing supply voltage. AC and DC versions are separate electrical configurations. Observe the five-minute continuous-duty limit. Confirm mounting, installation conditions and AC frequency where applicable; no weatherproof or continuous-duty rating is implied.
Typical applications
- Audible signalling in public or industrial premises within the stated supply and duty limits.
Specify your enquiry
For a focused quotation, include:
- UC4Z model, AC/DC supply voltage and AC frequency where applicable.
- Duty cycle, mounting location, required quantity and destination.
Download People Electric UC4 catalogue (PDF)