LC3-D TeSys Automatic Star Delta Motor Starter LC3-D TeSys Automatic Star Delta Motor Starter
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
LC3-D TeSys Automatic Star Delta Motor Starter LC3-D TeSys Automatic Star Delta Motor Starter
Search
Sold out
LC3-D TeSys Automatic Star Delta Motor Starter
Click to enlarge
Home Automation & Control Motor Manual Starters LC3-D TeSys Automatic Star Delta Motor Starter
Acti 9 iCT DIN Rail Household Modular Contactor
Acti 9 iCT DIN Rail Household Modular Contactor
Back to products
DW45 3P/4P Air Circuit Breaker 1000A-6300A Multiple Voltages
DW45 3P/4P Air Circuit Breaker 1000A-6300A Multiple Voltages

LC3-D TeSys Automatic Star Delta Motor Starter

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC3-D
Phase:3
Main Circuit Rating Current:9A ~ 95A
Number of Pole
Main Circuit Rating Voltage
SKU: 60102321078 Category: Motor Manual Starters
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

LC3 D LC3-D TeSys Star delta Reduced Voltage Starter equivalent to Chint QJX2 Star delta starter

   

Application 

LC3-D series start-deltra reduced voltage starter is suitable for starting motor in the circuit of AC 50/60Hz, voltage up to 660V and current up to 95A It is provided with a timer for automatic change over of star delta to reduce the voltage and current of motor starting.

 

Application 

LC3-D series start-deltra reduced voltage starter is suitable for starting motor in the circuit of AC 50/60Hz, voltage up to 660V and current up to 95A It is provided with a timer for automatic change over of star delta to reduce the voltage and current of motor starting.

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Number of Pole

3

Main Circuit Rating Voltage

380V, 220v, 120v, 24v

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for LC3-D TeSys Automatic Star Delta Motor Starter.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

LE1D 3-Phase DOL Magnetic Motor Starter
LE1D 3-Phase DOL Magnetic Motor Starter

LE1D 3-Phase DOL Magnetic Motor Starter

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LE1D
Electricity Type:AC
LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter
LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter

LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:QCX2 (LE1-D)
Electricity Type:AC
Sold out
3VE1 DZ108 Manual Motor Protection Circuit Breaker

3VE1 DZ108 Manual Motor Protection Circuit Breaker

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:3VE1
Phase:3
Main Circuit Rating Current:0.1A ~ 20A
Type:Moulded Case
Sold out
3VU Motor Protector Circuit Breaker

3VU Motor Protector Circuit Breaker

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:3VU1300 3VU1600
Breaking Capacity:20kA
Rated Voltage:380V
Type:Moulded Case
Sold out
3RV1 Manual Motor Starter Protector Circuit Breaker
3RV1 Manual Motor Starter Protector Circuit Breaker

3RV1 Manual Motor Starter Protector Circuit Breaker

Rated Frequency:50/60hz
Type:Motor Manual Starter
BCD Curve:C
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:3RV1
Poles Number:3
Breaking Capacity:10kA
QX4A Automatic Star Delta Reduced Voltage Motor Starter

QX4A Automatic Star Delta Reduced Voltage Motor Starter

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:QX4A
Sold out
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME

GV2MC IP55 Enclosure Box for GV2ME

Rated Frequency:50/60hz
Type:Moulded Case
BCD Curve:C
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:GV2ME
Poles Number:3
Breaking Capacity:16kA
GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker
GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker

GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker

Rated Frequency:50/60hz
Type:Motor Manual Starter
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:GV2ME GV3ME GV2P GV3P
Poles Number:3
Breaking Capacity:16kA
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • 3VE1 DZ108 Manual Motor Protection Circuit Breaker 3VE1 DZ108 Manual Motor Protection Circuit Breaker
  • QX4A Automatic Star Delta Reduced Voltage Motor Starter QX4A Automatic Star Delta Reduced Voltage Motor Starter
  • 3VU Motor Protector Circuit Breaker 3VU Motor Protector Circuit Breaker
  • GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...